![Fisher-Rosemount 3095FT Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/fisher-rosemount/3095ft/3095ft_manual_2300591131.webp)
7-9
Specifications and Reference Data
TEMPERATURE
SENSOR ASSEMBLIES
This section describes Series 68 and 78 RTDs available in
V
L
lengths
from 1 to 9 inches. Rosemount Inc. builds a full range of RTD sensors
available for use with the Model 3095FT. This information is provided
as a guideline to the sensors most likely to be used in the Model 3095FT
systems. See Product Data Sheet PDS 2654 for information concerning
sensors not listed in Table 7-4.
Series 68 RTD
Rosemount Series 68 RTD Temperature Sensors are used for
measurements from –148 to 752 °F (–100 to 400 °C). Series 68 sensors
are available in capsule, general purpose, and spring-loaded designs in
J
lengths from 1 to 24 inches.
Table 7-2 shows the interchangeability of the Series 68 RTD.
TABLE 7-2. Series 68
Interchangeability.
Platinum Element and
Lead Wire Configurations
Single-element temperature sensors have four lead wires and may be
used in 2-, 3-, and 4-wire signal conditioning systems.
±1.44 °F
(±0.80 °C)
at
–148 °F
(–100 °C)
±0.99 °F
(±0.55 °C)
at
–58 °F
(–50 °C)
±0.54 °F
(±0.30 °C)
at
32 °F
(0 °C)
±1.44 °F
(±0.80 °C)
at
212 °F
(100 °C)
±2.34 °F
(±1.30 °C)
at
392 °F
(200 °C)
±2.88 °F
(±1.60 °C)
at
500 °F
(260 °C)
±4.14 °F
(±2.30 °C)
at
752 °F
(400 °C)
Содержание 3095FT
Страница 1: ...R Model 3095FT HART Flow Transmitter 00809 0100 4015 English Rev B1...
Страница 2: ......
Страница 4: ......
Страница 45: ...3 13 Options and Accessories 3051 1006D03A FIGURE 3 5 Recharging the Battery 15 to 36 V dc 500 mA minimum...
Страница 98: ...Rosemount Model 3095FT HART Flow Transmitter 4 50...
Страница 117: ...5 19 Troubleshooting and Maintenance FIGURE 5 2 Replacing the Remote Power Supply Battery...
Страница 118: ...Rosemount Model 3095FT HART Flow Transmitter 5 20...
Страница 146: ...Rosemount Model 3095FT HART Flow Transmitter 7 24...
Страница 147: ...Appendix A 1 A Model 3095 Explosion Proof Installation Drawing Factory Mutual Drawing Number 03095 1025 Rev G...
Страница 148: ...Rosemount Model 3095FT HART Flow Transmitter A 2...
Страница 149: ...A 3 Appendix A...
Страница 150: ...Rosemount Model 3095FT HART Flow Transmitter A 4...
Страница 151: ...Appendix B 1 B Index of I S F M for 3095 and Index of I S F M for 03095 5000 Drawing Numbers 03095 1020 and 03095 5000...
Страница 152: ...Rosemount Model 3095FT HART Flow Transmitter B 2...
Страница 153: ...B 3 Appendix B...
Страница 154: ...Rosemount Model 3095FT HART Flow Transmitter B 4...
Страница 155: ...B 5 Appendix B...
Страница 156: ...Rosemount Model 3095FT HART Flow Transmitter B 6...
Страница 157: ...B 7 Appendix B...
Страница 158: ...Rosemount Model 3095FT HART Flow Transmitter B 8...
Страница 159: ...Appendix C 1 C Model 3095 Explosion Proof Installation Drawing CSA Drawing Number 03095 1024 Rev D...
Страница 160: ...Rosemount Model 3095FT HART Flow Transmitter C 2...
Страница 161: ...C 3 Appendix C...
Страница 162: ...Rosemount Model 3095FT HART Flow Transmitter C 4...
Страница 163: ...Appendix D 1 D Index of I S CSA for 3095 and Index of I S CDA for 03095 5000 Drawing Numbers 03095 1021 and 03095 1031...
Страница 164: ...Rosemount Model 3095FT HART Flow Transmitter D 2...
Страница 165: ...D 3 Appendix D...
Страница 166: ...Rosemount Model 3095FT HART Flow Transmitter D 4...
Страница 167: ...D 5 Appendix D...
Страница 168: ...Rosemount Model 3095FT HART Flow Transmitter D 6...
Страница 183: ......