![Fisher & Paykel Titan aerotech OD301MUS Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/fisher-and-paykel/titan-aerotech-od301mus/titan-aerotech-od301mus_service-manual_2295977026.webp)
- 26 -
4.
Diagnostics
4.1
Entering the Technician Mode
(a)
Ensure all oven modes and temperature displays are set to ‘OFF’.
(b)
Ensure no cooking auto functions are set.
(c)
Enter
User Set Mode
by pressing ‘
TIMER
’ and then the ‘
CLOCK
’ button, hold for
2 seconds.
(d)
Turn the oven mode knob counter clockwise one position.
(e)
Enter
Sales Mode
by pressing ‘
TIMER
’ and then the ‘‘
PROBE
’ button, hold for 5
seconds.
Note:
If left in Sales Mode, only the oven displays will operate.
(f)
Return oven mode knob back to original position.
(g)
Enter
Technician Mode
by pressing ‘
TIMER
’ and then the ‘
STOP TIME’
button.
Hold for 2 seconds.
(h)
The Oven Mode Display will now show “TECH SELECT”.
Note:
The clock display will show the version of software installed in the product.
(i)
You are now in Technician Mode, oven diagnostics can be carried out.
4.2
Exiting the Technician Mode
(a)
To exit Technician Mode at any time press any button other than ‘CLEAR’ or
‘TIMER’
4.3
Technician Mode Navigation
(a)
Ensure Oven Mode Display shows “TECH SELECT”.
(Refer to Section 4.1)
(b)
Use the Oven Mode knob to navigate through the 19 Tech Select positions.
Note:
If any position from 1 to 11 is selected then the components ON / OFF status is
displayed in the oven temperature display. Push the clock twist button to turn the
component ON or OFF.
When an element is turned ON the cavity temperature will be displayed instead of
“ON”.