background image

 

 

 
 
 

 

HotPort 

Firetide Installation Guide

 

HotPort 5020-M Mesh Node

 

 
 
 
 
 
 
 
 
 
 

 

 
 
 

Published March 2014 
(Revised 2016)

 

 

Содержание HotPort 5020-M Mesh Node

Страница 1: ...HotPort FiretideInstallationGuide HotPort5020 MMeshNode Published March 2014 Revised 2016...

Страница 2: ...e logo Reliableconnectivityanywhere HotPort HotPoint and HotClientarealltrademarksofFiretide Inc Allothertrademarksarethepropertyoftheir respective owners Informationinthisdocumentissubjecttochangewit...

Страница 3: ...alhazardsarethoseenvironmentswherethedangerof electrocutionisprobable Thisimageappearsbeforeeachelectrical hazard statement Warnings contain safety information that you must obey If you do notobeythei...

Страница 4: ...information Youmustalsohaveadministratoraccesstothemeshtobeabletoreceive technical support Thenexttableliststhecontactinformationforcustomersupport Worldwide customer support Days Hours Contact Americ...

Страница 5: ...contentsforaHotPort5020 Mmeshnode 4 PartsofaHotPort5020 Mmeshnode 5 Groundscrew 6 LEDs 6 Resetbuttonandpressurereliefvalve 6 Antenna connectors 7 Testbeforeyouinstall 7 Requireditemsthatarenotincluded...

Страница 6: ...rproof procedures 27 Tools and materials to weatherproof connections 28 Makingaweatherproofantennaconnection 28 Makingaweatherproofcabletonodeconnection 30 Troubleshooting 33 DFS licenses 33 Cannotsee...

Страница 7: ...5020 Mnodeisacost effectiveinfrastructuremeshnodethathastwo radiostodeliverupto25MbpsofUDPdata HotPort 5020 M supports Point to point Point to multipointamongHotPort5020 E and MandHotPort7010 7020 nod...

Страница 8: ...otPort 5020 M nodes can be used in these countries US Australia Indonesia Japan Malaysia Philippines Singapore South Korea Taiwan Thailand and Vietnam Note Ifyoutrytosetthecountrycodetoacountryotherth...

Страница 9: ...Preparing what you need to install Tomakesureyouhaveeverythingyouneedtosetupthemeshnode 1 Open the box 2 Removethecontents 3 Checkthecontentsfordamage 4 Checkthecontentsagainsttheboxcontentslist See...

Страница 10: ...s outdoors theycanbedamaged Damagefromincorrectdeploymentis notcoveredbytheproductwarranty TwoRP SMAtotype Nadapters Mount kit U bolts M6x1 0 80mm withflatwashers splitwashers nuts Claw tooth pole gri...

Страница 11: ...or 2 Connector 3 Power LED Radio2 Connector 1 Connector 2 Connector 3 ThenextpictureshowstheconnectorsonthebottompanelofaHotPort5020 M mesh node Rubbercapon antenna connector Port DC power Reset butto...

Страница 12: ...ernetportandtheDCpowerconnector LEDs ThepanelthathastheFiretidelogohastheseLEDs Radio1andRadio2 whichindicateradiostatus LEDbehavior Meaning Off Radio is not active Steadygreencolor Radioisworkingcorr...

Страница 13: ...Antenna connector 2 Antenna connector 3 Test before you install Youshouldsetupandtestthemeshnodesindoorsonatablebeforeyouinstall theminpermanentlocations Thebenefitsoftestsbeforeyouinstallinclude Make...

Страница 14: ...shnodesatonetime TodotestsandcapturedatawithHotViewProsoftware 1 Putthemeshnodes ona table 2 Attachthepowercabletoeachmeshnode Caution Youmustusethepowersupplythatcomeswiththemeshnode Ifyouuseadiffere...

Страница 15: ...thatallofthemeshnodesarevisibleinHotViewPro Ifyoucannotseeanyorallofthemeshnodes seethetroubleshooting information in the HotView Pro Product Configuration Guide 9 Setthecountry codeforeachnodetochang...

Страница 16: ...than0 8km 0 5mile Todeterminethelongestlink youmeasurethedistancebetweenthemeshnodesonamap suchas Google Earth Setthemulti hopoptimizationfeatureiftheremightbehiddennode interference Note Forinformati...

Страница 17: ...e youneedtouse 2 Phillips screwdriver Small adjustable wrench Wirecutterstocuttiewrapsaroundcables Cable ties Electricaltapeandbutylmasticorsiliconetapetoweatherproofthe connectors Otherequipmentyoumi...

Страница 18: ...epole antennacombination This distance ensures that the polewillnot contact a powerlineif it falls duringor after installation Selectequipmentlocationsthatallowsafeandsimpleinstallation Donotworkalone...

Страница 19: ...ncludingelectricalshockorpermanentdamageto equipment Warning Make sure that all safety equipment is in good condition Do notusebrokenordamagedtoolsorequipment Alwaysusesafework practicesandobeyallloca...

Страница 20: ...ound Preparing earth ground Warning A HotPort node must be correctly connected to earth ground Failure to do so can result in equipment damage injury or death Theproductwarrantydoesnotincludedamagefro...

Страница 21: ...culatethecorrectgaugeofwiretobeusedinthisprocedure Refertothe NationalElectricalCodeforgroundinginformation Caution Thecertified installer is responsiblefor the correct calculation ofthewiregaugeandot...

Страница 22: ...undlugtothenode Ground wire from antennaconnector3 Ground wire from the mesh node enclosure Ground screw 6 Crimpthelugthatholdsthewirefromantennaconnector3andthe enclosure Connecttoearthground Caution...

Страница 23: ...hthecablesthathaveintegratedlightningarrestors orattach thecablesandinstalllightningarrestors Makedriploopswithcables Installallgroundingequipment Loosenthe groundscrew tightenthe ground screw to secu...

Страница 24: ...orsonallunusedantennaconnectors 8 Fromtheantennacabletothedeviceenclosuremakeeachterminated antennaconnectorweatherproof Useelectricaltapeandbutylmasticor siliconetape 9 SupplyACpowertothemeshnode IfP...

Страница 25: ...tiontothenode The mountbrackethasmultipleholesandslots soyoucanusebolts straps orother materialstoattachthenode toasurface ImageA showstheside of theplate to whichthechassis is attached ImageB showsth...

Страница 26: ...etpiecewithhooks Toattach a node to a wall 1 Makesureyouhaveenoughspaceabovethemountbracketsoyoucanhang themountplatehooksontherails 2 Usefourscrewsormasonry anchorstoattachthemountbracketsecurelyto t...

Страница 27: ...Put the two U bolts through the holes inthe gripper 2 Oneach U bolt put a washer a lock washer and a nut Note A polewith a small diameter usuallyrequires a second nut to hold the bracketawayfromtheU b...

Страница 28: ...atehooksovertherailsofthemountbracket Hooks Theinstallationiscorrectifthenodedoesnoteasilymovefromsidetoside andtheconnectorsareorientedtotheground Note If you need to add other straps or a sling to i...

Страница 29: ...2 UselockwashersandnutstosecurethebrackettotheU bolts 3 Hangthenodewith thehooks overtherailofthebracket Hooks 4 WiththePhillipsscrewdrivertightenthefourcaptivescrewstosecurethe nodetothebracket Thein...

Страница 30: ...poleandthreadthemthroughthechannels betweenthemainpieceofmetalandtherails Channels Rails 3 Securethestraps 4 Hangthenodewith thehooks overtherailofthebracket Hooks 5 WiththePhillipsscrewdrivertightent...

Страница 31: ...atherproofing includes Sealingallantennaconnectorsandantennaconnectorterminators InstallingtheweatherizedEthernetconnector Usingaspraytopreventcorrosiononthebracketandmounthardware For weatherizing pr...

Страница 32: ...HotPort5020 Mnodeinstallation 26...

Страница 33: ...20 meshnodewithasunshield Antenna with weatherproof connector Weatherproof connectors Meshnodewithsunshield Best practice You can use colored tape for easy identification of the connectors fromthe mes...

Страница 34: ...mastictapeputdirectlyonthecable Vinyl electricaltapeasacoveroverthemastictapepreventsthemasticfrommelting in hot weather Rubbersplicingormastictape alsoknownasself amalgamating self sealing self fusin...

Страница 35: ...rethattheFiretidedeviceworks 5 Wrapalayerofelectrical tape stickyside out overthe connector fromthe end to approximately2 5 cm 1inch of cable Overlap the tape by 40 with eachturn Note Wrap the electri...

Страница 36: ...layerof electrical tapeoverthefirst layerofelectrical tape Theantennaconnectorisreadyforinstallationinanoutdoorenvironment Makingaweatherproofcabletonodeconnection You need to make weatherproof two co...

Страница 37: ...r 3 Ensurethatthecableandconnectors areclean Cleanoff oil water grease anddirtbeforeyoucontinue 4 Wrap a layer of electrical tape sticky side out over the arrestor to node connectorandwrapapproximatel...

Страница 38: ...or 6 Tightlywrapa layerof mastictapeovertheelectrical tape Makea 40 overlap on each turn Start from the base of the unit to at least 2 5 cm 1 inch of the cable 7 Wrap a layer of electrical tape smooth...

Страница 39: ...managethe device from HotView Pro network management software FormoreinformationaboutDFSmanagement refertotheHotViewProReference Manual CannotseeanodeinHotViewPro HotPort5020nodesarenotsupportedinsolu...

Страница 40: ...rference onthe same node is caused by antennasthat aretoo close Inthecaseofdirectionalantennas werecommendatleast1meter 3feet of physical separation Self interferencewithinameshhappenswhennodesoperate...

Страница 41: ...anelofthenode Forthisprocedureyouneed Paperclip stiff wire orthinpieceofplasticorwood suchasaskewer Computer with HotView Pro Ethernetcable Wrenchoryourfingerstoturnthepressurevalve ToresetaHotPort502...

Страница 42: ...ater check box the scheduler copies the firmware imagetothenodebutdoesnotactivatethefirmware Whenyouscheduleanupgradetime SchedulerOperation Later theHotView server ifitisrunning starts thejobatthesch...

Страница 43: ...rs andthenselect themesh or devicebyID or name Note Thesystemselectsallnodeswithinameshforsimultaneousupgrade becauseallofthenodeshavetorunthesamefirmware Ifanodeshouldnot receivetheupgradeimage youca...

Страница 44: ...ouuseadifferentpowersupply youvoidtheproductwarranty 4 Givethenodepower ThepowerLEDcomeson Thenodebootsandisreadytouseinoneminute 5 Attachstagingantennasappropriatetoyournetworkapplication Note Forspe...

Страница 45: ...ecountrycorrectly thedevice mightoperateina mannerthatisnotlegalorcreateproblems withotherwirelessdevices a Selectthecountryofoperationfromthedrop downlist b ClickSetCountryCodeNow Whenyousetthecountr...

Отзывы: