C.1 It can’t power off when press ON/OFF key.
★
Long-time press the ON/OFF key until LED flashes, and then loosens the button, the
fusion splicer will power off.
C.2several splices can’t be done with full battery electrical quantity.
★
Turn on power saving mode.
★
Memory effect or long-time storage that leads to the deduction of electrical quantity.
You can complete discharging the battery and then charge it again.
★
The service life of battery is terminated, please replace the battery.
★
Use the battery in low temperature environment.
C.3 Error in fusion splicer
★
Please refer to appendix B
C.4 Splice loss is too large
★
Clean the V groove, fiber pressure hammer and the retroreflector.
★
Replace the electrode bar.
★
Please refer to appendix A.
★
The fiber cutting angle, discharging condition and cutting degree will affect the splice
loss.
C.5 Displayer turns off suddenly.
★
When turn on power saving mode, the displayer will auto turn off after long-time not
operating the fusion splicer. Now press any button will l et t he f usion splicer r eturn to
normal working state.
C.6 Fusion splicer turns off suddenly.
★
When turn on power saving mode, the fusion splicer will auto turn off after long-time
not operating the fusion splicer.
C.7 Identify fiber error under AUTO mode.
★
AUTO mode can only applied to standard SM, MM and NZ fiber, when splice special
fiber, AUTO may fail to identify correctly.
C.8 Splice loss estimation is inconsistent with actual loss.
★
Splice loss estimation can obtain through calculating, it can reflect the fusion condition
and just used as a reference.
★
The optical component of fusion splicer need to be clean.
C.9 Heat-shrinkable tubing not shrinks entirely.
★
Extend the heating time.
C.10 How to cancel heating
36
36
The following information list some solutions to common faults, if users can’t solve the
issues, please contact with the manufacturer.
Appendix C
Common faults and solutions