the switching paddle has to be switched back into the OFF status afterwards manually.

The device is also able to report status changes to a controller (communication pattern 2) and to remotely 

operate other devices (communication pattern 5). The switch can be controlled by every Z-Wave device 

(communication pattern 1, 4 and 7). Any existing second switch can only be used for remote control of other 

actuators according to communication pattern 5 and not to control the local switch.

Associations

A

 Z-Wave devices control other Z-Wave devices. The relationship between one device controlling 

another device is called association. In order to control a different device, the controlling device needs to 

maintain a list of devices that will receive controlling commands. These lists are called  association groups 

and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event 

happens all devices stored in the respective association group will receive a common wireless command.

Association Groups:

1 external Switch No 1 (max. nodes in group: 16)

2 external Switch No 2 (max. nodes in group: 16)

3 (max. nodes in group: 1)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 

… 255 the value sent in the application shall be the desired value minus 256. For example: to set a 

parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value 

the same logic applies: Values greater than 32768 may needed to be given as negative values too.

All on/off function (Parameter Number 1, Parameter Size 1) Enables or disabled the all on / all off function

Value

Description

0

neither ALL ON nor ALL OFF are active

1

only ALL OFF is active

2

only ALL ON is active

255

ALL ON and ALL OFF are active (Default)

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 6 

Содержание FGS-221

Страница 1: ...rt homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act...

Страница 2: ...vailable space depends on the size of the traditional switch the dimensions of the wall box and the amount of additional cabling placed in this box This device is designed for a 3 wire system and need...

Страница 3: ...connected to the insert contact I The electrical load is then connected to the other pole of the 230 V power supply or with the second pole of the additional power supply The switch can be operated lo...

Страница 4: ...ert as shown in the schematics If a bistable switch is connected it has to stay connected until the switch is included into the Z Wave network It is also possible to use a double switch for local cont...

Страница 5: ...etwork Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Blinking red green LED indicates that the device is in factory re...

Страница 6: ...ion group will receive a common wireless command Association Groups 1 external Switch No 1 max nodes in group 16 2 external Switch No 2 max nodes in group 16 3 max nodes in group 1 Configuration Param...

Страница 7: ...200 Commands Sent to Association Group 1 Parameter Number 6 Parameter Size 1 Defines what status changes cause sending out a wireless command Zu allow double click function parameter 15 needs to be tu...

Страница 8: ...power down Parameter Number 16 Parameter Size 1 The device will or will not return to the last switch state after a power down Value Description 0 not return to previous state Default 1 return to pre...

Страница 9: ...in case of alarm 2 Enable on Alarm will switch on in case of alarm 3 Flashing on Alarm will switch on and off periodically for 10 minutes Default Temperature Alarm Set Relay 1 Parameter Number 33 Par...

Страница 10: ...ll switch off in case of alarm 2 Enable on Alarm will switch on in case of alarm Default 3 Flashing on Alarm will switch on and off periodically for 10 minutes Smoke Alarm Set Relay 2 Parameter Number...

Страница 11: ...utes Command Classes Supported Command Classes Basic version 1 No Operation version 0 Binary Switch version 1 Version version 1 All Switch version 1 Multi Channel version 2 Multi Channel Association v...

Страница 12: ...f bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled de...

Отзывы: