background image

1. Controllers control actuators
2. Actuators report change of status back to controller
3. Sensors report change of status of measured values to controller
4. Sensors directly control actuators
5. Actuators control other actuators
6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.

There are two different role a controller can have. There is always one single primary controller that is managing the 

network and including/excluding devices. The controller may have other functions - like control buttons - as well. All other 

controllers don't manage the network itself but can control other devices. They are called secondary controllers. The 

image also shows that its not possible to operate a sensor just from a remote control. Sensors only communicate with 

static controllers.

Product description

The Fibar Insert Switch allows controlling two independent loads both via Z-Wave wirelessly and locally 

utilizing a traditional wall switch. The device is placed in a wall box right behind the normal switch. The 

switch is not longer directly connected to the load but acts as input device for the Fibar insert that is 

controlling the load. The solution works with all switch design with or without neutral position as long as 

there is enough space in the wall box behind the switch. The device is just 15 mm height. The available 

space depends on the size of the traditional switch, the dimensions of the wall box and the amount of 

additional cabling placed in this box. This device is designed for a 3 wire system and needs a neutral wire in 

the wall box.

Before Device is installed

Please read carefully the enclosed user manual before installation of the radio-actuator, in order to ensure 

an error-free functioning.

ATTENTION: only authorized technicians under consideration of the country-specific installation 

guidelines/norms may do works with 230?Volt mains power. Prior to the assembly of the product, the 

voltage network has to be switched off and ensured against re-switching.

The product is permitted only for proper use as specified in the user manual. Any kind of guarantee claim 

has to be forfeited if changes, modifications or painting are undertaken. The product must be checked for 

damages immediately after unpacking. In the case of damages, the product must not be operated in any 

case. If a danger-free operation of the equipment cannot be assured, the voltage supply has to be 

interrupted immediately and the equipment has to be protected from unintended operation.

Installation Guidelines

The switch insert is designed to fit into standard circular European wall boxes with 60 mm diameter. With its 

15 mm height, it can be also mounted behind traditional wall switches. This wall switch serves as an 

external control switch to switch loads. The relay itself is realized in the insert.

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 2 

Содержание FGS-221

Страница 1: ...rt homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act...

Страница 2: ...vailable space depends on the size of the traditional switch the dimensions of the wall box and the amount of additional cabling placed in this box This device is designed for a 3 wire system and need...

Страница 3: ...connected to the insert contact I The electrical load is then connected to the other pole of the 230 V power supply or with the second pole of the additional power supply The switch can be operated lo...

Страница 4: ...ert as shown in the schematics If a bistable switch is connected it has to stay connected until the switch is included into the Z Wave network It is also possible to use a double switch for local cont...

Страница 5: ...etwork Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Blinking red green LED indicates that the device is in factory re...

Страница 6: ...ion group will receive a common wireless command Association Groups 1 external Switch No 1 max nodes in group 16 2 external Switch No 2 max nodes in group 16 3 max nodes in group 1 Configuration Param...

Страница 7: ...200 Commands Sent to Association Group 1 Parameter Number 6 Parameter Size 1 Defines what status changes cause sending out a wireless command Zu allow double click function parameter 15 needs to be tu...

Страница 8: ...power down Parameter Number 16 Parameter Size 1 The device will or will not return to the last switch state after a power down Value Description 0 not return to previous state Default 1 return to pre...

Страница 9: ...in case of alarm 2 Enable on Alarm will switch on in case of alarm 3 Flashing on Alarm will switch on and off periodically for 10 minutes Default Temperature Alarm Set Relay 1 Parameter Number 33 Par...

Страница 10: ...ll switch off in case of alarm 2 Enable on Alarm will switch on in case of alarm Default 3 Flashing on Alarm will switch on and off periodically for 10 minutes Smoke Alarm Set Relay 2 Parameter Number...

Страница 11: ...utes Command Classes Supported Command Classes Basic version 1 No Operation version 0 Binary Switch version 1 Version version 1 All Switch version 1 Multi Channel version 2 Multi Channel Association v...

Страница 12: ...f bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled de...

Отзывы: