![FIBARO FGS-221 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/fibaro/fgs-221/fgs-221_manual_2286550008.webp)
Value
Description
0
Not checked
1
Checked (Default)
Bistable Switch State (Parameter Number 13, Parameter Size 1) Defines the behavior of a connected
bistable switch
Value
Description
0
ON/OFF sets to change of key state (Default)
1
ON is active when contacts are closed and OFF is active when contacts are open
Type of Switch (Parameter Number 14, Parameter Size 1) Defines the type of switch attached to the device
Value
Description
0
mono-stable switch (Default)
1
bi-stable switch
Saving of switch state after power-down (Parameter Number 16, Parameter Size 1) The device will or will
not return to the last switch state after a power down
Value
Description
0
not return to previous state (Default)
1
return to previous state
General Alarm Set - Relay 1 (Parameter Number 30, Parameter Size 1) This defines the behavior of relay 1
in case of general alarms
Value
Description
0
Deactivated, devices does not react to alarms
1
Disable on Alarm - will switch off in case of alarm
2
Enable on Alarm - will switch on in case of alarm
3
Flashing on Alarm - will switch on and off periodically for 10 minutes (Default)
(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 8