General Alarm Set - Relay 2 (Parameter Number 40, Parameter Size 1) This defines the behavior of relay 2
in case of general alarms
Value
Description
0
Deactivated, devices does not react to alarms
1
Disable on Alarm - will switch off in case of alarm
2
Enable on Alarm - will switch on in case of alarm
3
Flashing on Alarm - will switch on and off periodically for 10 minutes (Default)
Flood Alarm Set - Relay 2 (Parameter Number 41, Parameter Size 1) This defines the behavior of relay 2 in
case of flood alarms
Value
Description
0
Deactivated, devices does not react to alarms
1
Disable on Alarm - will switch off in case of alarm
2
Enable on Alarm - will switch on in case of alarm (Default)
3
Flashing on Alarm - will switch on and off periodically for 10 minutes
Smoke Alarm Set - Relay 2 (Parameter Number 42, Parameter Size 1) This defines the behavior of relay 2
in case of smoke alarms
Value
Description
0
Deactivated, devices does not react to alarms
1
Disable on Alarm - will switch off in case of alarm
2
Enable on Alarm - will switch on in case of alarm
3
Flashing on Alarm - will switch on and off periodically for 10 minutes (Default)
Temperature Alarm Set - Relay 2 (Parameter Number 43, Parameter Size 1) This defines the behavior of
relay 2 in case of temperature alarms