Power Supply

230V ~50-60 Hz

Attachable Loads

2 * 8A (1750W), lower at very inductive or resistive 

loads.

IP Rating

20

Explorer Frame Support Yes

SDK

4.52.00

Device Type

Slave with routing capabilities

Generic Device Class

Binary Switch

Specific Device Class

Binary Power Switch

Routing

Yes

FLiRS

No

Firmware Version

1.3

Explanation of Z-Wave specific terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically 

Gateways, Remote Controls or battery operated wall controllers.

Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators 

and even remote controls.

Primary Controller — is the central organizer of the network. It must be a controller. There can be only one 

primary controller in a Z-Wave network.

Inclusion — is the process of bringing new Z-Wave devices into a network.

Exclusion — is the process of removing Z-Wave devices from the network.

Association — is a control relationship between a controlling device and a controlled device.

Wakeup Notification — is a special wireless message issued by a Z-Wave device to annonces that is is 

able to communicate.

Node Information Frame — is a special wireless message issued by a Z_Wave device to announce its 

capabilities and functions.

Disposal Guidelines

The product does not contain hazardous chemicals.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. 

Contact your local government for information regarding the collection systems available. If electrical 

appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and 

get into the food chain, damaging your health and well-being.

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 12 

Содержание FGS-221

Страница 1: ...rt homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act...

Страница 2: ...vailable space depends on the size of the traditional switch the dimensions of the wall box and the amount of additional cabling placed in this box This device is designed for a 3 wire system and need...

Страница 3: ...connected to the insert contact I The electrical load is then connected to the other pole of the 230 V power supply or with the second pole of the additional power supply The switch can be operated lo...

Страница 4: ...ert as shown in the schematics If a bistable switch is connected it has to stay connected until the switch is included into the Z Wave network It is also possible to use a double switch for local cont...

Страница 5: ...etwork Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Blinking red green LED indicates that the device is in factory re...

Страница 6: ...ion group will receive a common wireless command Association Groups 1 external Switch No 1 max nodes in group 16 2 external Switch No 2 max nodes in group 16 3 max nodes in group 1 Configuration Param...

Страница 7: ...200 Commands Sent to Association Group 1 Parameter Number 6 Parameter Size 1 Defines what status changes cause sending out a wireless command Zu allow double click function parameter 15 needs to be tu...

Страница 8: ...power down Parameter Number 16 Parameter Size 1 The device will or will not return to the last switch state after a power down Value Description 0 not return to previous state Default 1 return to pre...

Страница 9: ...in case of alarm 2 Enable on Alarm will switch on in case of alarm 3 Flashing on Alarm will switch on and off periodically for 10 minutes Default Temperature Alarm Set Relay 1 Parameter Number 33 Par...

Страница 10: ...ll switch off in case of alarm 2 Enable on Alarm will switch on in case of alarm Default 3 Flashing on Alarm will switch on and off periodically for 10 minutes Smoke Alarm Set Relay 2 Parameter Number...

Страница 11: ...utes Command Classes Supported Command Classes Basic version 1 No Operation version 0 Binary Switch version 1 Version version 1 All Switch version 1 Multi Channel version 2 Multi Channel Association v...

Страница 12: ...f bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled de...

Отзывы: