Page 59
Function confi guration.
First step: Confi gure the command and panel.
1. Press the
On/Off
button, the display will show the
Duox Relay
and
version.
2. Via the arrows we select the
1. COMMAND
menu and press
Ok.
3. Via the arrows we select the
AUTO ON
command and press
Ok.
Second step: Confi guration of the command´s origin (residence terminals).
The lock-release command, relative to the
residence terminals
sending them can be con-
fi gured as:
a) All installed terminals (ALL).
b) Terminals from a list (maximum 100 terminals).
c) Terminals included within a defi ned range (consecutive).
a) Confi guration: All installed terminals (ALL).
1. Via the arrows we select the
3. TERMINALS
menu and press
Ok.
2. Via the arrows we select
ALL
and press
Ok.
3. Upon turning the programmer off, the function is confi gured.
b) Confi guration: Terminals in a list (maximum 100 terminals).
1. Via the arrows we select the
3. TERMINALS
menu and press
Ok.
2. Via the arrows we select
LIST
and press
Ok.
3. Via the arrows we select the
3.2. TERM LIST
menu and press
Ok.
4. Via the arrows we select
ADD
and press
Ok.
5. Via the number buttons we enter the
address
of the terminal we want to add and press
Ok.
Notes:
- If you want to view the value entered for the address, select the 3.2 TERM LIST menu
and press Ok. Via the arrows we select LIST and press Ok.
- If we want to delete a terminal from the list, select the 3.2 TERM LIST menu. Via the
arrows we select ERASE
and press Ok. Via the arrows, select the terminal to delete
and press Ok.
6. Upon turning the programmer off, the function is confi gured.
Note:
- When the list is complete (100 terminals), the Relay On led fl ashes quickly.
c) Confi guration: Terminals included within a defi ned range (consecutive).
1. Via the arrows we select the
3. TERMINALS
menu and press
Ok.
2. Via the arrows we select
RANGE
and press
Ok.
3. Via the arrows we select the
3.1. RANGE START
menu and press
Ok.
4.
Via the numeric keypad, enter the
fi rst address in the range
and press
Ok.
5. Via the arrows we select the
3.1. RANGE END
menu and press
Ok.
6.
Via the numeric keypad, enter the
last address in the range
and press
Ok.
Note:
The last address should be greater than the fi rst one.
7. Upon turning the programmer off, the function is confi gured.
Содержание DUOX RELAY
Страница 1: ...DUOX RELAY advanced manual INSTALLATION MANUAL...
Страница 5: ...Page 5 Installation manual...
Страница 68: ...Avd Tres Cruces 133 46017 Valencia Spain...