Page 51
c) Confi guration: Terminals included within a defi ned range (consecutive).
1. Via the arrows we select the
3. TERMINALS
menu and press
Ok.
2. Via the arrows we select
RANGE
and press
Ok.
3. Via the arrows we select the
3.1. RANGE START
menu and press
Ok.
4.
Via the numeric keypad, enter the
fi rst address in the range
and press
Ok.
5. Via the arrows we select the
3.1. RANGE END
menu and press
Ok.
6.
Via the numeric keypad, enter the
last address in the range
and press
Ok.
Note:
The last address should be greater than the fi rst one.
7. Upon turning the programmer off, the function is confi gured.
Third step: Confi guration of the activation time.
To confi gure the activation time, follow point:
3.2 CONFIGURING ACTIVATION TIMES
3.3.2.2 ACTIVATION OF THE RELAY UPON RECEIVING A CALL TO RESIDENCE
COMMAND FROM A STREET PANEL .
Function description.
You can confi gure the relay to activate upon receiving a
call to residence
command from
a panel.
The panel, upon making a call, sends a call to residence command to the residence’s ter-
minal (or terminals). The relay, if confi gured this way, can activate upon receiving the call
residence command. The residence terminals can receive the call to residence command
from a specifi c panel or from all panels in the installation, understanding that this command
is sent individually to each terminal.
- The call to residence command, relative to the
residence terminals
receiving them can
be confi gured as:
* All installed terminals (ALL).
* Terminals from a list (maximum 100 terminals).
* Terminals included within a defi ned range (consecutive).
- The call to residence command, relative to the
panels
sending them can be confi gured as:
* All panels (they individually send each command, not all in the group).
For example: In the installation the panels are P1, P2, P3, P4 and P5. The residence
terminal can receive a call from Panel P1 or Panel P2 or Panel P3 or Panel P4 or
Panel P5. Upon confi guring the call to residence command in All panels, the relay
is activated when the call to residence command is sent from any panel.
* Only one panel.
For example: In the installation the panels are P1, P2, P3, P4 and P5. The residence
terminal can receive a call from Panel P1 or Panel P2 or Panel P3 or Panel P4 or
Panel P5. Upon confi guring the call to residence command in a single panel, for
example, Panel P4, only when Panel P4 sends the call to residence command is the
relay activated.