2.5.1.3 CALL GUARD UNIT FUNCTION
Function description.
You can install a button for calling the guard unit, and it can be installed far from the phone.
Via the terminal Set (button connected between the SET terminals and -), a call to guard unit
is made with the confi gured telephone´s original address, and with the confi gured guard unit
as destination.
Notes:
- If you want to confi gure with the integrated buttons on the relay (Min/All - Sec/Single), you
need a Duox telephone confi gured to send calls to the guard unit in Mixed mode. If you do
not have a telephone confi gured this way, you must do so with the Duox Programmer, see the
corresponding chapter in Section
“3. CONFIGURATIONS - FUNCTIONS: PROGRAMMING
WITH THE DUOX PROGRAMMER”
.
Confi gure the installation in Mixed mode so that the panels may make direct calls and the
terminals may make calls to the guard unit.
Function confi guration.
1.
Press the
PRG
button, the
C
led should light up.
2.
Press the
Sec/Single
button, the
C
LED should blink slowly.
3.
Press on a push button telephone the
lock-release
button (in stand-by and without having
received a call in the last 30 seconds), the
C
LED should remain off. This way you have
already confi gured the command attending to the relay. The guard unit´s address must
always be the same as the confi gured telephone has.
4.
Press the
PRG
button twice, the
D
led should light up.
5.
Press the
Sec/Single
button, the
D
LED should blink quickly.
6.
Make a call to the terminal you want to have the function. Upon making the call the
Relay
On
led turns on for about 1.5 seconds.
7.
Press the
PRG
button, all the leds must remain off. The function has been confi gured so
that when a button connected to the SET terminal is pressed (SET and -), a call is made
to the guard unit that has the confi gured telephone and the originating address is that
marked during the call.
Steps to change the terminal assigned the function.
1.
Press the
PRG
button twice, the
D
led should light up.
2.
Simultaneously press the
Min/All
and
Sec/Single
, the
D
led should remain off.
3. Repeat points 4 and 7 from the previous process.
Note:
- In the push-button confi guration mode, if no button is pressed the relay returns to standby
and all leds turn off after 300 seconds.