SwitchLinc V2 
Relay 

 

INSTEON On/Off 

 
 

 
For models: 
#2476S 

SwitchLinc V2 Relay 

Содержание 2476S

Страница 1: ...SwitchLinc V2 Relay INSTEON On Off For models 2476S SwitchLinc V2 Relay...

Страница 2: ...E THAN ONE SWITCHLINC Relay 18 Cross Linking in a 3 Way Circuit 18 ADVANCED FEATURES OF SWITCHLINC RELAY 19 Restoring Power to SwitchLinc Relay 19 Resetting SwitchLinc Relay to Its Factory Default Set...

Страница 3: ...Certification 32 Limited Warranty 32...

Страница 4: ...ation Reliable because every INSTEON device is a two way repeater And affordable not just because of low cost but because INSTEON also works with legacy X10 devices An INSTEON home grows in value with...

Страница 5: ...driver for the screws that hold SwitchLinc Relay in the ju A wire cutter and stripper if the switch you are replacing requires you to cut the wires A small Phillips screwdriver if you will be changing...

Страница 6: ...or removed the fuse for the circuit you are installing SwitchLinc Relay in Installing SwitchLinc Relay with the power on will expose you to dangerous voltages SwitchLinc Relay requires a small amount...

Страница 7: ...are installing SwitchLinc Relay into a multi way circuit where more than one switch controls the same load follow the instructions in the section Installing SwitchLinc Relay in a Multi Way Circuit be...

Страница 8: ...way circuits where there is no existing wiring Here is how a wired in three way circuit with two switches works w es added in the o learn more abo way circuits go to Google com or another search engin...

Страница 9: ...tion box o the actual lights that are being controlled cted to econdaries must be connected to NEUTRAL and LINE Black NEUTRAL White GROUND Bare Copper LINE Black NEUTRAL White LOAD Red Main Panel 120...

Страница 10: ...of the switches will have four wires c Disconnect the wires from the old switches If the wires cannot be detached by unscrewing them cut the wires where they enter the switch then strip inch of insula...

Страница 11: ...dary s LOAD wire to ensure that it won t connect to anything 5 Connect the SwitchLinc Secondary s NEUTRAL Wire Locate the group of NEUTRAL wires usually white in the rear of the box The old switch sho...

Страница 12: ...e is commonly red In the same junction box there will also be the two TRAVELER wires from the first box often both in the same cable sheath Identify the one TRAVELER wire black that you connected the...

Страница 13: ...switches will have four wires connected to them Two of the wires are TRAVELERS from the preceding switch and the other two are TRAVELERS to the next switch in the chain You will be converting the bla...

Страница 14: ...ically A A Second SwitchLinc Relay Press and hold the Second SwitchLinc Relay s Paddle Top for 10 seconds then release To confirm linking the Second SwitchLinc Relay will blink the top LED in its LED...

Страница 15: ...ON Devices to multiple of INSTEON Controllers To add an additional INSTEON Device to a scene controlled by SwitchLinc Relay simply follow the same procedure as above in Linking SwitchLinc Relay to a C...

Страница 16: ...hat it is wired to once and begin blinking the top LED in its LED Bar B ControLinc V2 Tabletop Controller Choose the ON OFF Button Pair you want to use for controlling SwitchLinc Relay Press and hold...

Страница 17: ...the OFF Button of the ON OFF Button Pair you used for controlling SwitchLinc Relay for 10 seconds To confirm that it is in Unlinking Mode ControLinc V2 s Status LED will begin blinking C KeypadLinc V2...

Страница 18: ...n the LED bar of the other switches it has been cross linked to Cross Linking in a Multi Way Circuit using Multi Link Mode For more than two switches multi link mode will allow you to save time For th...

Страница 19: ...2 If you are using SwitchLinc Relay to control any INSTEON Devices other than the light it is wired to unlink those Devices from SwitchLinc Relay See Unlinking a Controlled INSTEON Device from SwitchL...

Страница 20: ...m this step before SwitchLinc Relay s Linking Mode times out automatically 3 Once SwitchLinc Relay has received the preceding sequence three times SwitchLinc Relay will confirm that it has set its Pri...

Страница 21: ...rn off all modules that are members of that X10 Scene X10 Scene enabled modules will ignore ALL ON and ALL OFF commands for the X10 Scene Address Remotely Setting an X10 Scene Address 1 Using an X10 C...

Страница 22: ...Off The SwitchLinc Relay default mode is appliance mode To set the switch for the Lamp Mode 1 Using an X10 Controller send the CLEAR Sequence 2 Activate the SwitchLinc Relay manually or remotely by tu...

Страница 23: ...SwitchLinc V2 Relay User s Guide HOW TO USE SWITCHLINC RELAY Using the Paddle The Paddle Top makes your load go ON and the Paddle Bottom makes your load go OFF Page 23 of 32...

Страница 24: ...addle and LED Colors You can remove the front paddle and trim frame assembly before or after SwitchLinc Relay is installed During the changeover process the power and the load may remain on and operat...

Страница 25: ...he most protrusions facing toward the center of the frame Using only finger pressure snap the light pipe into the frame Installed incorrectly Installed correctly J If both light pipes are installed co...

Страница 26: ...tting weaker is to increase the coverage of the mesh network by introducing more INSTEON devices It is possible that some audio video products computers power strips or other electrical equipment may...

Страница 27: ...ff when you set the X10 Address for the product If turned on the BoosterLinc technology may INSTEON interfere with NOTE To disable BoosterLinc X10 Signal Amplification on these products 1 Press and ho...

Страница 28: ...INSTEON devices act as INSTEON Network repeaters My SwitchLinc Relay is not linking to or working with an INSTEON Controller or Device The INSTEON signal may be too weak Make sure you are not experien...

Страница 29: ...following the instructions in the section Setting the X10 Primary Address I m having difficulty performing advanced X10 programming The X10 MNOP house and unit codes were sent in the wrong order Don t...

Страница 30: ...oad Cross Link any number of SwitchLinc Relays or other INSTEON Controllers Setup Memory Non volatile EEPROM INSTEON Features INSTEON Addresses 1 hard coded out of 16 777 216 possible INSTEON Links 41...

Страница 31: ...ons 4 1 H x 1 8 W x 1 2 D Weight 3 6 oz Electrical Supply Voltage 120 Volts AC 10 60 Hertz single phase Surge Protection MOV rated for 150 Volts Power Wire Leads 6 16 AWG stranded 600V 105 C insulatio...

Страница 32: ...t with the RA clearly printed on the outside of the package and send the product along with all other required materials to SmartLabs Inc ATTN Receiving Dept 16542 Millikan Ave Irvine CA 92606 5027 Li...