![SmartLabs 2476S Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/smartlabs/2476s/2476s_user-manual_1297761021.webp)
SwitchLinc V2 Relay User’s Guide
ADVANCED X10 PROGRAMMING OPTIONS
You can remotely set up X10 Scene Addresses with an X10 Controller capable of sending an X10
address (house code and unit code)
without
sending X10 ON or OFF commands. The following
procedures will not work with a transmitter that sends the X10 address and an X10 command together.
X10 Controllers in which one button is pressed to turn an X10 device on or off WILL NOT WORK.
These procedures all begin by sending the same sequence of five X10 addresses, called the CLEAR
Sequence. After you send the CLEAR Sequence, you have about 4 minutes to finish the procedure
before automatic timeout.
About X10 Scene Address Programming
SwitchLinc Relay can be a member of up to 255 X10 Scenes. An X10 Scene Address is just another X10
address like the X10 Primary Address. When an X10 ON command is sent to an X10 Scene Address,
every X10 Scene-enabled module with that X10 Scene Address will turn on. Sending an X10 OFF
command to an X10 Scene Address will turn off all modules that are members of that X10 Scene. X10
Scene-enabled modules will ignore ALL ON and ALL OFF commands for the X10 Scene Address.
Remotely Setting an X10 Scene Address
1. Using an X10 Controller, send the CLEAR Sequence:
2. Activate the SwitchLinc Relay (manually or remotely) by turning it on. (Hint: a scene can trigger a
module to go off by turning the switch off during this sequence.)
3. Send the following X10 Address sequence:
4. Send the desired X10 Scene Address (house code and unit code) to lock in the new On-Level and
X10 Scene Address.
5. SwitchLinc Relay will flash the light it is wired to and blink an LED in its LED Bar, indicating that the
X10 Scene Address and On-Level have been set up.
Remotely Removing an X10 Scene Address
1. Using an X10 Controller, send the CLEAR Sequence:
2. Send SwitchLinc Relay X10 Primary Address (house code and unit code).
3. Send an X10 ON or OFF command.
4. Send the following X10 Address sequence:
O16
N16
M16
P16
M16
M16
N16
O16
P16
O16
N16
M16
P16
M16
O16
P16
M16
N16
5. Send the X10 Scene Address (house code and unit code) that is to be removed.
6. SwitchLinc Relay will blink an LED in its LED Bar, indicating that the X10 Scene Address has been
removed.