SwitchLinc V2 Relay User’s Guide
If the INSTEON Device is still available, unlink it from
SwitchLinc Relay by following the directions in the
section
Unlinking a Controlled INSTEON Device from
When I press a button on
my SwitchLinc Relay, it
takes a long time for
other INSTEON Devices
it is controlling to
respond.
You may have removed an
INSTEON Device that your
SwitchLinc Relay is trying to
operate. SwitchLinc Relay is
re-trying the missing
INSTEON Device.
Reset SwitchLinc Relay by following the directions in the
section
Resetting SwitchLinc Relay to Its Factory Default
, above.
My SwitchLinc Relay
doesn’t respond to X10
address A1 when I first
set it up.
Unlike previous X10-only
products, SwitchLinc Relay
does not have an X10
Primary Address set up at the
factory.
Set up an X10 Primary Address by following the
instructions in the section
I’m having difficulty
performing advanced
X10 programming
The X10 “MNOP” house and
unit codes were sent in the
wrong order.
Don’t hold down the buttons on your X10 controller too
long, to avoid duplicate codes being sent.
SwitchLinc Relay is
locked up
A surge or excessive noise
on the powerline
Resetting SwitchLinc Relay to Its Factory Default
, above.
SwitchLinc Relay is
getting warm to the
touch.
It is normal for wall
controllers to get warm (but
not hot).
SwitchLinc Relay will dissipate about 1 Watt per 100
Watts controlled. Using metal junction boxes, removing
insulation around the outside of the box, or controlling a
smaller load can help lessen the heat.
If you have tried these solutions, reviewed this User’s Guide, and still cannot resolve an issue you’re
having with SwitchLinc Relay, please:
•
Search our online knowledge base at
.
•
Call our Support Department at 866-243-8018.
•
Page 29 of 32