background image

1

Figure 1 – Bendix

®

 R-12DC

®

 Relay Valve Exploded View

*Crack Pressure is the amount of control 

pressure required by the valve to initiate 

air delivery.  For Crack pressures other 

than 4 psi, a differential spring is used 

in the assembly to produce the required 

valve response.

 

 

(Models designed to have a 4 psi crack 

pressure do not require a differential spring.)

Primary Control

Port 1/4 NPT

Secondary

Control Port

 1/4 NPT

Cap Screw

Torx

® 

Screw

Differential Spring

(Controls Crack Pressure*)

(Not required for Most 

Models. 

See Below

.)

Vertical 

Delivery 

Ports 

Supply Port 

Horizontal Delivery 

Ports

Differential Springs

BENDIX

®

 R-12DC

®

 RELAY VALVE MAJOR MAINTENANCE KIT

Kit Contents

Item No.

Description

Qty.

1

Valve Spring

1

2

Check Valve Guide

1

3

Check Valve

1

4

O-Ring

1

5

O-Ring

1

6

O-Ring

1

7

Inlet & Exhaust Valve

1

8

Valve Retainer

1

9

Spring

1

10

O-Ring

1

11

O-Ring

1

12

Exhaust Cover

1

13

Retaining Ring

1

14

Lubricant (Not Shown)

1

6

7

8

2

3

4

5

1

9

13

12

11

10

Valve 

Cover

Double 

Check 

Cover

Relay Piston

Valve Body