43
ALARM
CODE
DESCRIPTION
POSSIBLE CAUSE
SOLUTION
Er17
Air flow regulation not achieved
• We could have a problem in
the smoke outlet
•
The air inlet is totally or
partially plugged, or has been
channeled and has a lot of
pressure loss
•
Dirty brazier
•
The boiler takes air from an
unstrained entrance: open or
poorly closed door, hopper
without pellet, etc.
•
The smoke passages of the
boiler are very dirty
•
The smoke extractor has lost
potency
•
•
Problems with the flow
sensor or its connection
(Sond message appears)
•
Airflow sensor broken
Review all the possibilities listed
in the Er02 Check the boiler and
installation
Check the cleanliness of the boiler
and the smoke outlet In case of
repeating this alarm very often or
not being able to reset it, notify
the Technical Service
Er23
Probe body water stove
•
Defective or poorly wired
probe
Notify the Technical Service
Er39
Flow meter sensor
broken
•
It could appear when the
boiler is turned off if the flow
sensor breaks down during
operation
If this problem persists the Er41
will appear
Er41
The minimum airflow has not been
reached during the “Check- up”
check
•
We could have a problem in
the smoke outlet
•
The air inlet is totally or
partially plugged, or has been
channeled and has a lot of
pressure loss
•
Dirty brazier
•
The boiler takes air from an
unstrained entrance: open or
poorly closed door, hopper
without pellet, etc.
•
The fume passages of the
boiler are dirty
•
The smoke extractor has lost
its potency
•
Problems with the flow or
its connection (the message
Sond)
Review all the possibilities listed
in the Er02 Check the boiler and
installation
Check the cleanliness of the boiler
and the smoke outlet In case of
repeating this alarm very often or
not being able to reset it, notify
the Technical Service
Er42
Excessive airflow during
“Check-up” (Check)
•
It could appear if we had an
excessive shot in the chimney,
or if we are forcing the air inlet
for combustion.
Review and correct installation In
case of repeating this alarm
often, or not getting
reset it, notify the Technical
Service
Er52
Error module I/O 12C
•
Point-in-time communication
failure between the connection
module and the electronic
board
Disconnect a few seconds from
the mains and reconnect If this is
repeated often
alarm, or you can not reset,
notify the S.A.T. (Technical
Service)