16
5.4.1 MEASURES TO CROSS ENCLOSURES
The smoke duct must cross one or more enclosures of the premises depending on where the device is going to
be installed.
The size of the holes that need to be opened depends on the diameter of the duct and the enclosure to be crossed.
Once the tube has passed the remaining space must be filled with insulation (rock wool, ceramic fiber.)
Insulating thickness
[mm]
Diameter of holes to be made
[mm] for an outlet tube Ø80 mm
Wall in flammable wood, or with
flammable parts
100
280
Cement wall or ceiling
50
180
Brick wall or ceiling
30
140
5.4 HOME FIRE PREVENTION
•
The manufacturer’s instructions for both the installation and use of the boiler must be complied with, in addition to
all the corresponding safety regulations and regulations must also be complied with. Otherwise, FERLUX is not
responsible in the event of any accident.
•
It is recommended to have out of the heat focus (at least 1.5m away) any combustible or flammable element such
as wooden beams, furniture, curtains, flammable liquids, etc. A protective layer of insulating and non-
combustible material should be placed in the heat focus area where flammable or heat-sensitive coatings are
in place.
•
Periodic cleaning of the boiler and the smoke ducts must be carried out since the soot and other accumulated
combustion residues could enter into combustion.
•
In the event of a chimney fire, use the appropriate extinguishing systems to put out the fire, or contact the firefighters
for their intervention.
•
If fumes occur during the operation of the boiler, ventilate the room, and check the tightness of the elements of the
same and the chimney. Once verified if the problem persists consult with the SAT to adopt a solution.
•
In the case of having a flammable floor (parquet type, floating flooring.) or heat-sensitive soils, it is necessary
to place a protection that separates the stove from the ground. This protection should be of a fire-resistant material
such as marble, sheet steel, tiles, etc. This material has to be able to resist without breaking due to the weight
of the boiler. It shall be at least 2 mm and shall be at least 150 mm from the boiler on the sides and rear and 300
mm from the front of the stove.
•
Below is a table with the minimum safety distances that must always be guaranteed on a mandatory basis
Safety distances to flammable
material
Distancias de seguridad al material
no inflamable
A
Safety distances to non-flammable
material
B
200 mm
100 mm
C
1500 mm
750 mm
D
500 mm
200 mm