42
ALARM
CODE
DESCRIPTION
POSSIBLE CAUSE
SOLUTION
Er09
Low pressure in the water
•
The working pressure of the
boiler is below 600mbar. (This
error does not appear if the
hydro-stove is on lock or off
and the pump is stopped)
Check boiler pressure
If the problem persists for a long
time call the Technical Service
Er10
High pressure in the water
•
The working pressure of the
boiler is above 2800mbar.
Check the boiler pressure and
check that the circulation pump
is working properly. If this error
persists, notify Technical Service
Er11
Update DATE and TIME
•
It may appear the first time
the hydro- stove is connected
to the network or after several
days disconnected
Update time and day of the week
See section 6.2.3
Er12
Power failure
IF THE BRAZIER
IS PRACTICALLY EMPTY
•
There is little pellet in the
hopper
•
A “cave” has formed in the
hopper and the pellet does
not reach the endless
•
•
The load auger has been
stuck and/or charging motor
does not rotate
IF THE BRAZIER HAS BEEN
LEFT
FULL OF PELLET (urns burned)
•
Wet or poor quality pellet
•
Damaged ignition resistance
and/or connection cable
Reset the error Make sure that the
pellet reaches the endless and / or
throw in case of being
necessary
If after several attempts pellets do
not fall into the burner, notify the
Technical Service
Empty and clean the brazier,
reset the alarm and attempt a
new start
Check the condition and quality of
the pellet
If it does not start after two
or three attempts, notify the
Technical Service
Er15
Power outage
•
A power outage has occurred
for a long time while the boiler
was running, or during ignition
Reset the error and restart.
In case of repeating this alarm
often, or not being able to reset
it, notify the S.A.T. (Technical
Service)
Er16
Communication error
•
There has been some
communication failure
between board and screen
Check the cable and connections
to board and display