13
5. INSTALLATION INSTRUCTIONS
The installation of the FERLUX Hidromatic pellet boiler must be carried out only by qualified personnel, following the
manufacturer’s instructions and in accordance with all applicable rules and regulations in force. Otherwise, FERLUX
is not responsible in case of any accident.
We must choose the location of the boiler in such a way that the route to the vertical connection of the smoke outlet is as short
as possible.
Both in the device and in the smoke ducts we can have high temperatures, so you must follow the manufacturer’s
instructions to prevent possible fires and dangerous situations. (See section 5.4 HOME FIRE PREVENTION.)
We must also consider the supply of air for combustion, as well as maintain adequate environmental conditions within the
enclosure. (See section 5.6 VENTILATION AND AIR INTAKE.)
THE USE OF FUELS SUCH AS CHIPS, CHOPPED FIREWOOD, BRANCHES IN GENERAL IS PROHIBITED.
THE USE OF UNAUTHORIZED FUELS CAN HARM THE BOILER AND COMPROMISE ITS
PERFORMANCE LEADING TO THE CANCELLATION OF THE WARRANTY AND THE END OF THE
MANUFACTURER’S LIABILITY FOR THE PRODUCT.
The use of inadequate fuel causes:
•
Accumulation of pellet in the burner.
•
Dirt on the burner and smoke evacuation ducts.
•
Bad combustion.
•
Decreased boiler performance.
•
Increased fuel consumption.
•
The normal operation of the boiler is not guaranteed.
•
Need to do more cleaning and maintenance in the boiler.
4.3 PELLET STORAGE
To ensure a smooth combustion, it is necessary to keep the pellets in a dry environment and not too cold. Wet and/or cold
pellets reduce fuel power and efficiency and require greater cleaning maintenance of the burners, body and chimney.
Take special care in the storage of the pellets, as well as in their displacement, avoiding the formation of sawdust
and that the bags break, since if this happened it could increase the humidity and the proportion of sawdust and the calorific
characteristics of the fuel would possible decrease
características caloríficas del combustible.
THE USE OF PELLETS THAT DO NOT COMPLY WITH THE BEFORE MENTIONED REGULATIONS MAY
HARM THE BOILER AND COMPROMISE ITS PERFORMANCE, LEADING TO THE CANCELLATION OF
THE WARRANTY AND THE END OF THE MANUFACTURER’S RESPONSIBILITY FOR THE PRODUCT.
THE HIDROMATIC BOILER MUST ALWAYS BE INSTALLED BY AUTHORIZED PERSONNEL. ITS
IMPLEMENTATION WILL BE CARRIED OUT BY THE AUTHORIZED SAT OF FERLUX.
Содержание HIDROMATIC
Страница 1: ...Calidez de Vida hIDROMATIC AUTOMA TIC PELLET BOILER COD 0503 R1 INGL S...
Страница 2: ...2...
Страница 47: ...47...