3. GENERAL SAFETY RULES

- The lifting tower is an industrial element designed to raise loads vertically, it must NEVER 

be used as a platform elevator for people.
- Only place the lifting tower on firm flat grounds checking it is in vertical position. Do not 

use wedges or any strange elements to balance the hoist.
- Check legs are correctly assembled and secured by their safety pins.
- Never raise a load without first checking it is correctly supported and centred on the appro-

priate lifting tower supports, so the load only acts vertically.
- Never surpass the maximum load capacity indicated on the lifting tower characteristics label 

and on this instruction manual.
- If there is a likelihood of strong wind or gusts, place the lifting tower on the ground and 

secure it with the aid of straps.
- Never fix a strap over a vehicle or any other element which might move.
- Never use a ladder over the lifting tower or lean against it for any kind of work.
- Beware of any kind of projection above the lifting tower like cornices, balconies, luminous 

signs, etc. It is very important to avoid the presence of cables below the lifting tower’s working 

height.
- Never move the lifting tower when the load is raised. It is inadvisable to make any kind of 

movement, even small positioning adjustments.
- Never use the lifting tower over any mobile surface or vehicle.
- Before using the lifting tower, check the cable’s state, which must not present any broken 

threads or compression. NEVER use defective cables and change cable if in doubt. Only use 

steel cable as described on this manual.
- Fix the lever when the load is raised.
- Neither grease nor lubricate the winch brake mechanism. Braking disks were greased with a 

special heat and pressure resistant grease. No other products must be used to prevent negative 

influence on brake functioning.
- All sections of the lifting tower must be lowered to transport it.

Содержание ELV-200/6

Страница 1: ...No Instrucciones Instructions LIFTING TOWERS Fabricante Manufacturer FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fen...

Страница 2: ...2 2 FENIX STAGE S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain...

Страница 3: ...bility the conformity of the product Name Model Description to which this declaration refers as per the following regulations CE 2006 42 EG Person empowered to compile the technical file and authorise...

Страница 4: ...sions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusiones Conclusions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusio...

Страница 5: ...unto 3 p g 8 seguir las instrucciones de uso ver punto 4 p g 9 un manteniminto peri dico ver punto 5 p g 10 conocer los sistemas de prevenci n ver punto 7 p g 11 BGV C1 is a regulation for staging and...

Страница 6: ...DE SEGURIDAD 8 4 INSTRUCCIONES DE USO 9 5 MANTENIMIENTO 9 6 RIESGOS ESPEC FICOS 10 7 SISTEMAS DE PREVENCI N 10 INDEX 1 INTRODUCTION 11 2 GENERAL DATA 11 2 1 Technical data 11 2 2 Applicable regulation...

Страница 7: ...cos Denominaci n TORRE ELEVADORA Modelo ELV 200 6 Caracter sticas t cnicas Altura m xima 6 40m Altura m nima 1 92m Carga m xima 200kg Carga m nima 25kg Material Acero seg n EN 10305 5 rea de la base a...

Страница 8: ...po de trabajo Tenga cuidado con todo tipo de salientes por encima de la torre elevadora como cornisas balcones letreros luminosos etc Es muy importante evitar la presencia de cables por debajo de la a...

Страница 9: ...deseada Inmediatamente despu s mover el gatillo de seguridad A en posici n cerrada S hasta que haya llegado al final del tramo y as sucesivamente entre las distintas posiciones de cada una de las barr...

Страница 10: ...e su territorio 6 RIESGOS ESPEC FICOS Fallo del sistema de freno Puede producirse por deficiencias en el siste ma de frenado o por una mala instalaci n Si deja de funcionar puede provocar un riesgo im...

Страница 11: ...las torres de forma segura Sobre ca da de objetos a distinto nivel golpes y o contusiones con objetos El riesgo de ca da de objetos a distinto nivel puede prevenirse con la utilizaci n de elementos d...

Страница 12: ...V 200 6 Technical characteristics Maximum height 6 40m Minimum height 1 92m Maximum load 200kg Minimum load 25kg Material Steel EN 10305 5 Open base area 2 12 x 2 12m Closed base area 0 47 x 0 47m Wei...

Страница 13: ...r element which might move Never use a ladder over the lifting tower or lean against it for any kind of work Beware of any kind of projection above the lifting tower like cornices balconies luminous s...

Страница 14: ...s move the safety pin A to clo sed position S until the end of the section has been reached Go on successively to the different positions of each of the bars until the desired height is reached In cas...

Страница 15: ...the manufacturer or an authorised distributor within your territory 6 SPECIFIC RISKS Braking system failure May occur due to braking system deficien cies or bad installation If it stops working it co...

Страница 16: ...ifferent level knocks and or contusions from objects The risk of objects falling to a different level can be prevented using homologated safety ele ments e g a safety pin which fixes the interior prof...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21 NOTAS NOTES LIFTING TOWERS...

Страница 22: ...22 NOTAS NOTES LIFTING TOWERS...

Страница 23: ...23 NOTAS NOTES LIFTING TOWERS...

Страница 24: ...FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixstage com www fenixstage com www fenixstage com...

Отзывы: