Test report no. 19011738 

Page 

1

 of 

82 

 

 

 

EUT: ID ISC.ANT1710690-1.0  
          Crystal Gate Excellence 

FCC ID: 

PJMLRM2500

 

FCC Title 47 CFR Part 15 

Date of issue: 2019-05-29 

 

Date: 2019-03-11 

Created: P4                                  Reviewed: P9                          Released: P1 

Vers. No. 1.19 

TÜV NORD Hochfrequenztechnik GmbH & Co. KG 
LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany 

Tel.: +49 221 88889500 

 

 
 
 
 
 
 
 
 
 
 

Annex acc. to FCC Title 47 CFR Part 15 

relating to 

FEIG ELECTRONIC GmbH 

ID ISC.ANT171090-1.0 Crystal Gate Excellence 

 

Annex no. 5 

User Manual 

 

Functional Description  

 

 
 

Title 47 - Telecommunication 

Part 15 - Radio Frequency Devices 

Subpart C 

 Intentional Radiators 

ANSI C63.4-2014 

ANSI C63.10-2013 

 
 
 
 

 

 
 
 

 

 

Содержание ID ISC.ANT1710/690 Crystal Gate Excellence...

Страница 1: ...No 1 19 T V NORD Hochfrequenztechnik GmbH Co KG LESKANPARK Geb ude 10 Waltherstr 49 51 51069 K ln Germany Tel 49 221 88889500 Annex acc to FCC Title 47 CFR Part 15 relating to FEIG ELECTRONIC GmbH ID...

Страница 2: ...M2500 FCC Title 47 CFR Part 15 Date of issue 2019 05 29 Date 2019 03 11 Created P4 Reviewed P9 Released P1 Vers No 1 19 T V NORD Hochfrequenztechnik GmbH Co KG LESKANPARK Geb ude 10 Waltherstr 49 51 5...

Страница 3: ...IDENTIFICATION M91020 0e ID B Ende der Liste f r Textmar ke Deckb INSTALLATION ID ISC ANT1710 690 Crystal Gate Excellence Type A and B...

Страница 4: ...forts errors may not be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not...

Страница 5: ...byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this may cause faulty operation of...

Страница 6: ...f the People Counter ID ISC ANT GPC 12 5 3 Available Antenna Types 14 6 Installation and Wiring 15 6 1 Mounting Preparation 15 6 2 Installing the Antenna 17 6 2 1 Dimensions of the Antenna 17 6 2 2 Dr...

Страница 7: ...50 8 1 Installation ID ISC ANT GPC E2 50 8 2 Installation and Connections 52 8 3 Configuration and Test 59 8 3 1 Connecting Several People Counters 59 8 3 2 Configuration and Test in ISO Host Mode or...

Страница 8: ...ounter ID ISC ANT GPC 75 11 2 USA FCC and Canada IC 76 11 2 1 Antenna ID ISC ANT1710 690 Crystal Gate Excellence 76 11 2 2 People Counter ID ISC ANT GPC 77 11 3 USA and Canada UL 78 Annex 79 Annex A T...

Страница 9: ...on must be in accordance with national legal requirements and local electrical codes When working on devices the valid safety regulations must be observed Please observe that some parts of the device...

Страница 10: ...D ISC ANT1710 690 Crystal Gate Excellence A B Revision History of Documentation Page 8 of 8 2 Revision History of Documentation Revision History of Documentation Revision Date Description 0 15 04 2019...

Страница 11: ...orting lying on the flat side of the packaging can cause damage to the device The pallet has to be adapted to the size and the number of antennas In no case shall the packaging stand out of the range...

Страница 12: ...oisture and liquids contain minerals that corrode electronic circuits and damage transparent plastic parts Protect the antenna from high temperatures Mount the antenna away from radiators and other he...

Страница 13: ...eive antenna for the ID ISC LRM2500 reader However it is also possible to operate it with other readers at a transmission frequency of 13 56 MHz and an output impedance of 50 The read ranges and tunin...

Страница 14: ...nd the People Counter to a second gate aisle The people counter has two counters per aisle The values of the incoming and outgoing persons are registered separately Fig 1 Gate People Counter Structure...

Страница 15: ...na A direct connection from the GPC to the host is not required All commands from the host to the people counters are embedded in the piggyback command of the reader Generally there are two possibilit...

Страница 16: ...4 000 00 People Counter and radar detector for antenna ID ISC ANT1710 690 incl mounting and cabling set optional ID ISC ANT GPC E2 Extension Radar Detector Order No 4718 000 00 Second radar detector w...

Страница 17: ...stance below 1 5 m the antennas must be shielded from each other Otherwise the read range will be significantly reduced The antennas must have a minimum distance of 20 cm to all larger metal parts At...

Страница 18: ...IDENTIFICATION ID ISC ANT1710 690 Crystal Gate Excellence A B Installation and Wiring Page 16 of 16 Step 1 Step 2 Fig 4 Opening the antenna base...

Страница 19: ...nstallation and Wiring Page 17 of 17 6 2 Installing the Antenna 6 2 1 Dimensions of the Antenna The overall dimensions of the antenna are shown in Fig 5 Fig 5 Antenna outside dimensions All dimensions...

Страница 20: ...nna foot The dimensions are shown in Fig 6 Fig 6 Floor plate dimensions All dimensions are in mm with general tolerance to ISO 2768 m middle The size and type of the anchors depend considerably on the...

Страница 21: ...7 Cable routing at the antenna sides 6 2 3 Installing the Antenna Base and Antenna Body The antenna is mounted on the floor Please note that the antenna conductors in the middle of the antenna body mu...

Страница 22: ...n allows the detection of a tag moving on a horizontal line through the reading area of the gate The tag orientation is arbitrary The tags are detected along a horizontal axis of motion in certain are...

Страница 23: ...he tags should be at least ISO card size 46 mm x 75 mm The activation field strength of the tags should be less than or equal to 60 mA m The distance from tag to tag should be greater than 10 cm If th...

Страница 24: ...e of less than 8 m the readers must be synchronized See Application Note Synchronizing RFID Long Range Readers using the digital in outputs N10311 xe ID B pdf Gate with antenna Type A and Type B Gate...

Страница 25: ...r automatic doors or other moving objects can strongly influence the counting of the people counter If a people counter is installed in the antenna the antenna conductors in the middle of the antenna...

Страница 26: ...radar sensor antenna distance 1m Standard configuration All values are approximate values depending on the size of the objects the behavioral reflection of the floor and the material of the moving ob...

Страница 27: ...ined values of the actual values can vary If major deviations are noticed first the sensitivity of the radar sensors should be gradually reduced 7 3 Gate Configuration and Setup Using Antennas 7 3 1 R...

Страница 28: ...upply at X11 of the terminal board Also a connection between X13 GPC out of the terminal board in Antenna Type A and X13 GPC out of the terminal board in Antenna Type B must be installed to supply the...

Страница 29: ...oard assignment is given in Annex A Terminal Assignment Terminal Board NOTE A reverse polarity could damage the device or the In Outputs The connection between antenna Type A and Type B must be made w...

Страница 30: ...enna Type B Fig 17 Connection of the antennas at single gate Possible configuration for a double gate with 3 antennas X13 GPC out of the terminal board in Antenna Type A and X13 GPC out at the 1st Ant...

Страница 31: ...in parallel The coax cables have fixed lengths and must not be shortened and therefore need to be tied into small loops see Fig 19 Tie all cables as far away from the antenna conductor as possible Th...

Страница 32: ...d preferably be connected shortly Unused cable lengths should be tied in antenna Type B Tie all cables as far away from the antenna conductor as possible The cables must never touch the antenna conduc...

Страница 33: ...positions and antenna connections Antenna 1 Type A Lower loop is connected by default with output 1 and upper loop with output 2 of the multiplexer orange Antenna 2 Type B Lower loop has to be connec...

Страница 34: ...the cover from the antenna base Step 1 Step 2 Fig 22 Removing the antenna base covers The jumpers JP21 JP24 of the Dynamic Antenna Tuning board should be set factory setting as follows Function Jumper...

Страница 35: ...t communication With structured shielded cabling CAT 5 cables should be used This ensures reliable operation at 10 Mbps or 100 Mbps The prerequisite for using TCP IP protocol is that each device has a...

Страница 36: ...r To tune the antennas open the ISOStart software and read out the current configuration of the reader Step Action Note 1 Start ISO Start Software 2 Select Detect 3 Select Run without change Note This...

Страница 37: ...IDENTIFICATION ID ISC ANT1710 690 Crystal Gate Excellence A B Typical Antenna Configuration Page 35 of 35 Step Action Note 5 Select Expert Mode and confirm with OK 6 Select Logical View...

Страница 38: ...e aisle 6 two aisles 8 three aisles Antenna Active Time 100 x 5ms Receiver Channel Upper and Lower Sideband 3 Set by clicking on Apply 4 Transponder Configure the parameters as following Driver here I...

Страница 39: ...In the Detect Reader window select the interface COM Port 1 BusAdr 0 and then click on Detect 3 Use Settings to enter the configuration Single Mode Number of Antennas e g 4 Click on with Multiplexer N...

Страница 40: ...nd a transponder At this point the noise level and performance of the gate are tested 7 4 1 Checking the Noise Level Step Action Note 1 Activate antenna 1 with the command Function Unit Commands Multi...

Страница 41: ...lues are inaccurate check the following Are all cables pulled tight and in good contact Are the ferrite ring cores installed on the antenna cable Are the cables routed as specified Are there other RFI...

Страница 42: ...ltiplexer output 1 Use adhesive tape or similar 2 Activate antenna 1 with the command Function Unit Commands Multiplexer Parameter Channel Select Cascade Level 1 Output Channel of Input 1 1 3 Confirm...

Страница 43: ...starts with checking the reading range outside the gate see Fig points and as far as the configuration and location allow If the tag is oriented parallel to the antenna at the outside a reading range...

Страница 44: ...na distance cabling metal near the antennas is detuning or interfering with them the antennas are not properly tuned the noise level is too high Vmax Vmin 20 mV the transponder is too insensitive detu...

Страница 45: ...1 Setting the Alarm Buzzer The solution provided here presumes that the alarm indicator buzzer is switched through the digital output 2 X2 on the ID ISC LRM2500 BB reader The pulse duration can be se...

Страница 46: ...iplexer the antenna is connected to The bus address is automatically set after the complete gate system has been set up and configured and a 0x64 System Reset command has been executed in one of the R...

Страница 47: ...t Buffered Read Mode 4 Digital IO Idle Mode OFF Idle Flash Mode 1Hz Setting Time with Setting Time set time of output 2 for alarm duration 10 means 1 second e g 10 x 100ms Assign Output 2 to antenna 1...

Страница 48: ...f the alarm should occur by a transponder with valid AFI byte you have to configure the reader as follow ISO 15693 Selection Mask Set Enable AFI Set the value for the AFI in field AFI1 e g 01 Note Up...

Страница 49: ...rly all transponder models of the ISO 15693 family To disable the transponder simply write a different code to it than for valid transponders that trigger an alarm Step Action Note 1 Select Commands 2...

Страница 50: ...any interface connection Serial Ethernet To activate the Buffered Read Mode proceed as follows Step Action Note 1 Select Configuration 2 Operation Mode Mode Buffered Read Mode Data Selector UID Anten...

Страница 51: ...ation mode from ISO Host to Buffered Read or Notification Mode 3 Changing the number of output channels of the multiplexer if reader is in one of the automatic modes After the automatic bus addressing...

Страница 52: ...People Counter 8 1 Installation ID ISC ANT GPC E2 Content of the ID ISC ANT GPC E2 1 1 piece radar connection cable 2 1 piece radar module 3 2 piece spilt rivet 3 0mm 4 1 piece cable clip Step Action...

Страница 53: ...the cable clip 4 Install radar module with split rivet 5 The sensitivity of the radar module will be set automatically by the GPC after powering up the gate system To check set the sensitivity see als...

Страница 54: ...f the ID ISC ANT GPC 1 1 piece connection cable people counter terminal board 2 1 piece radar connection cable 3 1 piece LED connection cable 4 1 piece People Counter Board 5 1 piece radar module 6 1...

Страница 55: ...tal Gate Excellence A B Installation Gate People Counter Page 53 of 53 Step Action Note 1 Disconnect LED connection cable at the terminal board and cut the cable tie in the antenna foot 2 Disconnect L...

Страница 56: ...N ID ISC ANT1710 690 Crystal Gate Excellence A B Installation Gate People Counter Page 54 of 54 3 Remove the cable clip beside the LED controller 4 Remove the 2 other cable clips by pulling them out w...

Страница 57: ...55 5 Install People Counter Board into antenna with screws for plastic in antenna No 4 The 2 GPC must be installed in antenna No 4 otherwise the Automatic Bus Addressing will fail 6 Plug GPC connecti...

Страница 58: ...ter Page 56 of 56 7 Attention Note Do not touch the antenna surface of the Radar module to avoid damaging the electronic components and soiling 8 Connect radar connection cable with X1 of Radar module...

Страница 59: ...matically by the GPC after power up the gate system To check set the sensitivity see also 8 3 2 Configuration and Test in ISO Host Mode or Buffered Read Mode Step 8 12 Connect LED cable with X1 of LE...

Страница 60: ...ge 58 of 58 will be automatically done after power up the gate system or the command System Reset in one of the Automatic Modes The successful detection could be checked with the command Get reader In...

Страница 61: ...nas used in parallel A 5 6 pin shielded twisted pair cable must be used for connection Example LiYCY TP 3x2x0 25 The cable is content of antenna Type B The bus address of the people counter will be de...

Страница 62: ...arity even Number of Databits 8 Number of Stopbits 1 3 Confirm with Apply 4 Peripheral Devices Gate People Counter Set Antenna Type HPDx Mode Enable GPC to New Generation 5 Confirm with Apply 6 Periph...

Страница 63: ...A High 0F Very high Default First Read out actual setting of sensitivity If needed change to new sensitivity by Write the new value into the GPC A People Counter Reset command must be sent to confirm...

Страница 64: ...es should be 0 15 Walk through the gate from both directions 16 Select Command Get People Counter Values 17 Confirm with Send 18 Counter values will be displayed In ISO Host Mode and Buffered Read Mod...

Страница 65: ...al Devices Set People Counter and Notify Counter to True 3 Confirm with Apply 4 Operating Mode Select Notification Mode 5 Confirm with Apply 6 Set IP Address and Port for Notification Mode IP Address...

Страница 66: ...IDENTIFICATION ID ISC ANT1710 690 Crystal Gate Excellence A B Installation Gate People Counter Page 64 of 64 9 Therefore you will have to set both ports have the same address at the TCP Settings...

Страница 67: ...one direction For this reason it is necessary that the radar module antenna faces the direction of the transponder which could trigger the alarm In buildings e g libraries the radar module faces into...

Страница 68: ...ered Read Mode or Notification Mode 3 Confirm with Apply 4 Operating Mode Set Trigger enable Source Input No 2 Trigger TriggerUse set to Start Trigger Hold Time e g 20x100ms 2sec 5 Confirm with Apply...

Страница 69: ...8 3 4 Using the Trigger Function of the Gate People Counter is connected to input 2 of the reader and X4 TRG of the terminal board otherwise the direction mode will not work Step Action Note 1 Select...

Страница 70: ...ple Counter Page 68 of 68 8 3 6 Detection Area of the Direction Mode Tested with Gate width 150cm Radar sensitivity Very High Transponder I Code SLiX 45x75mm Fig 31 Detection are of the direction mode...

Страница 71: ...pproval in accordance with EN 300 330 is still possible in all 46 CEPT countries The CEPT countries are Albania ALB Andorra AND Austria AUT Azerbaijan AZE Belarus BLR Belgium BEL Bulgaria BUL Bosnia a...

Страница 72: ...be configured as follows depending on the installation location Parameter USA Canada Europe Air Interface RF Power maximum 4 W RF Modulation 15 Transponder RF Modulation ISO MODE MOD 10 RF Data coding...

Страница 73: ...of attaching points Recommended anchors Recommended minimum load capacity of the floor fastener 2 10 mm 5000 N anchor Unevenness of the acrylic plate 10 mm Tolerances on thickness and Quality ISO 7823...

Страница 74: ...ENVIRONMENTAL CONDITIONS Temperature range Operating Storage 25 C to 50 C 25 C to 70 C SM3 APPLICABLE STANDARDS RF approval Europe USA Canada EN 300 330 FCC Part 15 RSS 210 EMC EN 301 489 Safety Low...

Страница 75: ...5 lb with packing ca 50 g 100 g 0 22 lb with packing ELECTRICAL DATA Supply Voltage 24 V 15 Power Consumption max 2 VA Operating Frequency 24 125 GHz RF transmitting power 16 dBm e i r p Outputs 1 Opt...

Страница 76: ...HANICAL DATA Type Desktop power supply with IEC socket according IEC60320 C13 3 pin Housing Plastic Dimensions W x H x D 58 x 30 5 x 132 mm 1 mm 2 3 x 1 2 x 5 2 0 04 Weight approx 345 g Enclosure rati...

Страница 77: ...4 53 EU RE Directive dated 16 th of April 2014 Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489 Class 2 The technical data of the ID ISC LRM2500 BB reader built into the ID IS...

Страница 78: ...ursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment ge...

Страница 79: ...ice Usually this is followed by the following RSS caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this eq...

Страница 80: ...IDENTIFICATION ID ISC ANT1710 690 Crystal Gate Excellence A B Approvals Page 78 of 78 11 3 USA and Canada UL The following picture indicates the label position Fig 32 Position of the label...

Страница 81: ...2 Pin 5 GND X2 Pin 6 Buzzer X2 Pin 7 Shield X3 MUX 24V DC Multiplexer X3 Pin 1 24V 24 V DC Multiplexer X3 Pin 2 GND GND Multiplexer X5 GPC in Connection Cable to People Counter or LED X5 Pin 1 24V DC...

Страница 82: ...R2500 X2 Pin IN2 brown X2 Pin 4 Reader LR2500 X2 Pin IN2 grey X2 Pin 5 Reader LR2500 X3 Pin Out2 E pink X2 Pin 6 Reader LR2500 X2 Pin Out2 C white X2 Pin 7 Reader LR2500 X2 GND black X3 MUX 24V DC Mul...