Always stop the motor of the generator when filling it with fuel.

Never fill the fuel tank while smoking or near a naked flame.

Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling

with fuel.

Keep the fuel in an appropriate recipient and sheltered from any sources of fire.

Carry out filling in a safe place, and slowly open the fuel cap to release the pressure which has

built up inside the tank. Wipe up any drops of petrol that have spilled before starting the motor.

To prevent fire, move the generator at least 4 metres away from the area for filling with fuel.

Make sure that the fuel cap is tightly closed before starting.

Do not keep petrol in the tank for a long time.

While using or transporting the generator, make sure you keep the generator upright, otherwise

the fuel may escape from the carburettor or the fuel tank.

Electrical safety

Before each use ensure that the load to be connected does not exceed the power of the current

produced by the generator.

To avoid electric shock, you must follow the following instructions:

Do not touch the generator with wet hands.

Do not run the generator under rain or snow.

Do not run the generator near water.

Connect the generator to earth. Use a sufficiently thick conductor for the earth wire.

Do not operate the generator in parallel with another generator.

If using electrical extensions, make sure that they are sufficiently thick to transport the current

and that they are used correctly.

The connection of a generator used for auxiliary power to the electrical installation of a

building must be performed by a qualified electrician, and in conformity to the provisions of the

applicable laws and norms in the field of electricity. Incorrect connections will cause leakage of the

current from the generator into the lines of the public electricity company. Such leakage could

electrocute the workers of the public electricity company working on the network or other persons in

contact with the line during a power cut. Also, when the public power supply is re-established, the

generator can explode, catch fire or generate fires in the building’s electrical installation.

Before connecting electrical devices to the generator, make sure that their voltage

specifications and frequency of functioning correspond to the technical characteristics of the

generator. There may be damage if the device connected is not designed to function with a voltage

tolerance of +/- 10% or a frequency tolerance of +/- 3 % compared with those of the generator.

Protection of the environment

You must periodically check the silencer (Before doing this, switch off the generator and let it

cool completely). A damaged silencer increases noise.

Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose.

The fuel for this machine is combustible and explosive. After stopping the machine, you must

handle the remaining fuel correctly and meet local environmental requirements.

To dispose of residual fluids, proceed as follows:

Close the fuel tap

Drain fuel from the fuel tank

Empty carburettor fuel

05

Содержание FGHI3500RS

Страница 1: ...ORIGINAL INSTRUCTIONS EN USER GUIDE CAUTION Read this manual before using this machine PETROL INVERTER GENERATOR FGHI3500RS LOW POWER GENERATING SET...

Страница 2: ...BEFORE OPERATION 10 6 START THE ENGINE 12 7 OPERATING THE GENERATOR 14 8 SHUT OFF THE ENGINE 18 9 MAINTENANCE 19 10 TRANSPORTATION WAREHOUSING 23 11 TROUBLESHOOTING 24 12 SPECIFICATIONS 26 13 CIRCUIT...

Страница 3: ...as this can get caught in the machinery as it runs Use safety equipment Wear protective gear such as an anti dust mask non slip safety shoes a helmet or hearing protection Stay vigilant watch what yo...

Страница 4: ...cause burns Pay attention to the warnings on the generating set Engine exhaust gases are toxic Do not operate the generating set in unventilated rooms When installed in ventilated rooms additional req...

Страница 5: ...t and that they are used correctly The connection of a generator used for auxiliary power to the electrical installation of a building must be performed by a qualified electrician and in conformity to...

Страница 6: ...n Fill in engine oil It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death This symbol indicates the surface is very hot and no...

Страница 7: ...the fuel switch to start position Turn on the engine switch Pull outward the choke cable Gently pull the handle until you feel resistance then quickly pull the handle to start the generator According...

Страница 8: ...manent part of the generator and should be kept with it if the generator is resold Please pay special attention to the following text WARNING This symbol is displayed if you do not follow the correct...

Страница 9: ...4 PARTS IDENTIFICATION 09...

Страница 10: ...gency high quality 4 stroke engine oil which must meet or exceed US automobile manufacturer s requirements of the American Petroleum Institute classification SG SF levels Choose the appropriate oil th...

Страница 11: ...e accidentally shutdown we recommend that you check the oil level regularly WARNING Gasoline is extremely flammable and explosive under certain conditions Please refuel in the ventilated place and tur...

Страница 12: ...replace the filter and then follow the opposite action to install the air filter BE CAUTIOUS Never run the engine without a filter or dirt will enter the engine through the carburetor and cause rapid...

Страница 13: ...areas the air fuel mix in a standard carburetor is relatively thick so the engine operating performance will reduce while the fuel consumption increases At this point you can adjust the main jet on th...

Страница 14: ...comply with the applicable laws and regulations Otherwise the power of the generator may impact on the public circuit If the power company employees or others touch the wire in the meantime it will le...

Страница 15: ...operating conditions the power output indicator green is on If the generator is overloading or the connected device is internally faulty the power indicator green will go off and the overload indicat...

Страница 16: ...elative humidity 30 Only in the specified cooling and ambient temperature the generator can be loaded to the rated power If the operating conditions do not meet the requirements of the standard or the...

Страница 17: ...rt beside the battery When connecting the charging cable to the car battery disconnect the battery ground wire first Remove the cable and then connect to the ground wire on battery after charging is c...

Страница 18: ...em is designed to prevent damage to the engine due to insufficient oil The oil alarm system automatically shuts down the engine before the oil in the crankcase drops to the safety line although the st...

Страница 19: ...t contains toxic carbon monoxide NOTICE Please use authorized spare parts The use of inferior parts will damage the engine Maintenance schedule Please do the maintenance within the specified month or...

Страница 20: ...one operation Oil Change When the engine is warm you can quickly and completely discharge the oil BE CAUTIOUS Make sure that the engine switch and the fuel switch are off before draining the oil Loos...

Страница 21: ...mmable and explosive under certain conditions Check the air filter core to make sure it s clean and the performance is normal Remove the side maintenance cover screws open the side maintenance cover R...

Страница 22: ...park plug with different heat value Maintenance of Muffler Fireproof Net Dirty muffler will affect the effect of the generator and the power of the engine To ensure the normal operation of the generat...

Страница 23: ...ight If the generator is placed in a sealed compartment the high temperature inside the compartment may cause the fuel to evaporate and cause an explosion Do not transport the generator on a rough roa...

Страница 24: ...re to replace the wire Use one end of the clip to clamp the metal part of NOTICE If the generator cannot be started for the first time when the oil is added or the oil is changed the oil alarm indicat...

Страница 25: ...evice work Shut off the generator and wait until the overload indicator turns off then start again or press the reset button to restart the generator Replace the device Get the device repaired Is DC p...

Страница 26: ...evel LpA 74 79 dB A K 0 79dB A Sound power level LwA 94 79 dB A K 0 79dB A Guaranteed sound power level 96 dB A Generator set AC out put Voltage 230 V AC Frequency 50 Hz AC rated output power COP 3 0k...

Страница 27: ...13 CIRCUIT DIAGRAM 27...

Страница 28: ...5 88 CE Philippe MARIE PDG 28 Serial number 20230403705 20230403928 Instytucja zawiadomiona 0905 Intertek Deutschland GmbH Stangenstra e 1 70771 Leinfelden Echterdingen Tel 49 711 27311 0 E Mail gs in...

Страница 29: ...he user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information co...

Страница 30: ...pairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456C...

Страница 31: ...sary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair stat...

Страница 32: ...BUILDER SAS 32 rue Aristide Berg s Z I du Casque 31270 Cugnaux France MADE IN PRC...

Отзывы: