Keep the fuel filter clean, and change the oil of the motor regularly.
Periodically check the installation of the connections and the tightness of the fixations,
re-tightening them if necessary.
Clean the components of the air filter periodically, and replace the air filter when necessary.
Remove any electrical equipment that is plugged in before starting or stopping the generator.
Before transporting the generator, you must empty the fuel tank.
Maintenance and repair of the generator must be carried out by a qualified technician from an
authorised after-sales service centre.
WARNING
: when you start the generator with the cord, watch out for sudden changes in the
rotation of the motor!!! Risk of wounding!!! Never cover the generator when it is running. The
cut-out mounted on the generator has the aime of reducing the risk of electric shock. If it needs to
be replaced with another cut-out, the latter must correspond to the technical specifications of the
generator. Due to important mechanical constraints, it is necessary to use a flexible sheathed cable
with a strong rubber protective layer (conforming to IEC 245-4) or a similar cable. If using an
electrical extension cable, the total length of the extension must not exceed 60m when the section
of the wire is 1.5mm
2
and must not exceed 100m when the section of the wire is 2.5mm
2
.
Additional requirements for low-power generating sets for use by laymen
Protect children by keeping them at a safe distance from the generating set.
Fuel is combustible and easily ignited. Do not refuel during operation. Do not refuel while
smoking or near naked flames. Do not spill fuel.
Some parts of the internal combustion engine are hot and may cause burns. Pay attention to the
warnings on the generating set.
Engine exhaust gases are toxic. Do not operate the generating set in unventilated rooms. When
installed in ventilated rooms, additional requirements for fire and explosion protection shall be
observed.
Before use, the generating set and its electrical equipment (including lines and plug connections)
should be checked to ensure that they are not defective.
Protection against electrical shock depends on circuit breakers specially matched to the
generating set. If the circuit breakers require replacement, they should be replaced with a circuit
breaker having identical ratings and performances characteristics.
Due to high mechanical stresses, only tough rubber-sheathed flexible cable (in accordance with
IEC 60245-4) or the equivalent should be used.
The user shall conform to regulations of electrical safety applicable to the place where the
generating sets are used.
The user must respect the requirements and precautions in the case of resupply by generating
sets of an installation, depending on existing protective measures in this installation and
applicable regulations.
Generating sets should only be loaded up to their rated power under the rated ambient
conditions.
Prior to commencing maintenance work it shall be ensured that untimely start-up is not possible.
Security measures when filling the fuel tank
The fuel is extremely flammable and poisonous.
This generator only uses petrol (gasoline); any other kind of fuel will damage the motor.
Do not overfill the tank with petrol to avoid spilling. If you notice a spill, it must be wiped up
completely with a dry cloth before starting the motor.
If you swallow fuel by mistake, if you inhale fuel vapours or if you get drops of fuel in your eyes,
see a doctor immediately. If a certain quantity of fuel is spilt on your skin or clothing, wash or
change your clothes.