2. QUICK START
WARNING
Only use outdoors
. The generator emits carbon monoxide, a toxic colorless and odorless gas
that can cause death or serious injury.
Ensure that the generator is placed horizontally.
Never work in the rain, snow or other humid environment.
Turn off the generator and avoid cigarettes, sparks, fire or explosion while refueling.
Check before start
Remove the oil access door, unscrew the dipstick to check the oil. If oil level is below the bottom
of the dipstick, add the recommended oil (oil capacity: 0.45L). Use a strong detergency,
four-stroke engine oil and choose proper viscosity of the oil according to your area's average
temperature.
Install side access panel.
Unscrew the fuel tank cap to add gasoline to the fuel tank.Please use unleaded
petrol or above 87# gasoline. Not add too fast, so as not to spill gasoline. And to prevent dirt,
dust or water into the tank. Tighten the fuel tank cap after the addition was complete.
Be careful
Do not use two-stroke gasoline or dirty gasoline.
Start the generator
1. In the following way to start the generator.
Recoil start:
Turn the fuel switch to start position.
Turn on the engine switch.
Pull outward the choke cable
Gently pull the handle until you feel resistance, then quickly pull the handle to start the generator.
According to the ambient temperature, push the choke cable inward after the starting the
generator.The lower the ambient temperature is, the slower the inward pushing is. The higher the
ambient temperature is, the faster the inward pushing speed is. Make sure the engine does not
turn off when pushing inwards.
2. When the output indicator lights on the control panel is on, the generator can
be used. Before connecting any load, the generator should be grounded. Please use a thick
cable to the ground terminal on the generator control panel is connected to an external
ground source.
3. Make sure all equipment is turned off and the switch in order to ensure that the equipment is
intact, confirm the use of electrical appliances does not exceed the total power rating of the
generator.
4. Connect your device to a suitable outlet generator control panel.
Turn off Generator
Note
Turn the ignition key to “OFF” position, the generator will stop immediately in any condition.
1. Turn off the generator in the following instructions.
Turn off and unplug the connected equipment.
Turn off the engine switch.
07
Содержание FGHI3500RS