Note
:
Normal maintenance interval
;
In areas where pollution is severe, check and repair frequently.
The above regular maintenance schedule is calculated at ambient temperature of 25°C. If the
ambient temperature exceeds 30°C, reduce the load power of the generator or shorten the time
interval for replacing the oil (choose one operation).
Oil Change
When the engine is warm, you can quickly and completely discharge the oil.
BE CAUTIOUS
Make sure that the engine switch and the fuel switch are off before draining the oil.
Loosen the oil drain screw, drain the oil.
Install the oil drain tube.
Fill the recommended oil, check the oil level.
After filling a new oil, shake the generator about a few times to ensure that the float of the oil
alarm system works properly.
Oil capacity: 0.45L
Wash your hands with soap and water after you touch the oil.