FCI WATERMAKERS, INC.
58
Maintenance & Repair
STORAGE PROCEDURES
Flush the membranes with fresh water weekly to keep them wet.
WINTERIZING PROCEDURE
If the system will be exposed to freezing temperatures, the system
must be drained of all product water and rinsed with a solution of
product water with 20% food-grade glycerin (propyline glycol).
WARNING: FREEZING TEMPERATURE
The system must be protected from freezing if it will be exposed to
temperatures below 32º Fahrenheit (0º Celsius). Freezing temperatures
(below 32º F / 0º C) will cause extensive damage to the system as the water
expands within the system during the freezing process. Resulting damage to
the system caused by freezing temperatures is the liability of the operator.
DO NOT subject the system to temperatures below 32º Fahrenheit (0º
Celsius) unless the system has been rinsed with a solution of product water
with twenty percent (20%) food-grade glycerin (propylene glycol).
STORAGE AND WINTERIZING PROCEDURES
Invariably there will be times when the watermaker will not
be used. During this time, it is recommended that the system
be shut down and certain precautions are taken. By following
these simple instructions, your FCI System will continue
to provide you with fresh water for years to come.