This page introduces the R1 ROC (R1 Reverse Osmosis
Controller) that works with the user to operate the watermaker.
R1 ROC OVERVIEW
The DTS
+SOLO
is controlled by the
R1 ROC
(
R1 Reverse Osmosis Controller),
specially designed for watermakers. This controller can be run either locally
via the display, or remotely via remote display or remote IP access.
The R1 ROC is designed to continuously monitor all inputs and control all
outputs for proper machine operation, notifying user of warnings, alarms,
and shutdowns on all displays. The R1 ROC also provides diagnostics,
system overview, and production statistics for the operator.
The R1 ROC is designed to make machine operation as simple as possible
for the operator. Once the operator places the machine into production
with the appropriate setpoints, the R1 ROC automatically sequences all
controlled devices in order to ensure the proper amount of fresh water is
delivered. In addition, the R1 ROC monitors water quality, flow rates, filter
life, pressures, and pump status to ensure safe and reliable operation.
Operation, machine setup, and calibration are all performed via the display, with factory
default settings stored permanently in the system, and adjustable settings user savable.
SAFETY
The R1 ROC has a couple different ways to ensure the safety of the personnel
operating the unit and also the safety of the unit itself. There are two types
of alarms that will be activated depending on the severity of the issue.
• Alarm
• Shutdown
Alarm
– This is used to alert the user that an item needs to be addressed immediately,
otherwise the system will shutdown. An example would be if the Product TDS is higher
than the setpoint: if left alone, the system will safety shut itself down to avoid damage.
Shutdown
– This is used to protect both the user and machine: if a
condition arises that is considered unsafe, the unit will immediately
shutdown. An example would be the high pressure shutdown: if the system
reaches its high pressure limit, the unit will immediately shutdown.
DISPLAY OPERATIONAL OVERVIEW
The FCI display has been specially selected for the marine environment. It is
designed to not interfere with marine electronics and is fully dimmable for
night time operation. The display utilizes a resistive touch screen: unlike most
touch screens, the display relies on the press action of your finger in order to
make contact with the screen. This allows the user to be able to activate the
screen even with gloves on, and allows for better overall screen design.