Adjustments
8
The configuration menu
The configuration menu of the MLS 508 summarizes important parameters and settings for
the control system in general and for operating the individual sensor types in particular.
In addition, you will find information on the different calibration procedures for all sensors
used in the system and the machine hydraulics.
To enter the
configuration menu
press the function
key F4
“Config.“
in the working window for 4 seconds.
8.4.2 Min-pulse calibration
In this menu item the operator can set the min-pulse, i.e. the smallest drive impulse required
to move the hydraulic cylinder by the smallest possible amount. These settings can be
carried out automatically by the system (only the two control loops left and right) and
manually by the user (all control loops). Furthermore, an automatic min-pulse calibration
requires a mounted and connected cross slope sensor.