7 Working with the MLS 508
57
5) Carry out a zero adjustment:
Press the UP key and the DOWN key of the
relevant control loop simultaneously until the
display first reads “Set” and, after another two
seconds, “0.0”.
Now release both keys and the system will
take over the actual value measured by the
sensor as target value and will assign both
measurements the value 0.0. You have carried
out a zero adjustment.
The green bar of the valve light is on.