38
6 First steps
3) Press the function key F3
(Enter) to save the selection or press the function key F4
(Exit) to exit without making any changes. After either key is pressed, the software returns to
the working window.
Saving the selection and returning to the working window
Proceed in analogy with the above explanations when changing the sensor for the right
machine side.
6.6.2 Sensor selection in automatic mode
In automatic mode you can seamlessly switch directly between the two sensors
selected last. In case no second sensor has been selected or is no longer active the
sensor selection menu appears. Meanwhile, the automatic control is
not
switched
off!
By pressing and holding the respective sensor selection key for four seconds the
sensor selection list can be accessed in automatic mode.
It is recommended to choose the sensor to be used temporarily before starting to
work. It should be set accordingly.
Application:
When reaching a position where a grade sensor cannot be worked with
anymore, you can switch to the cross slope sensor and back again via a
key stroke.