Maintenance, 10h
4812159701_D.pdf
2021-03-16
Sprinkler system/Drum
Check
Figure. Front drum
1. Nozzle
1
Start the sprinkler system and make sure that none of
the nozzles (1) are clogged. If necessary, clean
blocked nozzles and the coarse filter placed by the
water pump (2). See next section.
Newer machines can have sprinkler systems with dual
sprinkler pipes and sprinkler pumps as standard.
Cleaning the coarse filter
2
3
Figure. Pump system, front frame
right side
1. Coarse filter
2. Stop cock
3. Drain cock kran, filter
4. Water pump
5. Drain cock
6. Extra pump (optional)
1
4
6
5
To clean the coarse filter (1) open the drain cock (3)
on the filter and allow any dirt to run out.
If necessary close the cock (2) and clean the filter and
filter housing. Check that the rubber gasket in the filter
housing is intact.
After inspecting and cleaning, reset and start the
system to check that it works.
There is a drain cock (5) in the space for the pump
system. This can be used to drain the tank and the
pump system.
An extra pump (6) can be installed in case the
standard water pump stops working. See section for
emergency watering.
To drain the complete sprinkler system, see section for
Watering system - Draining, 2,000 h.
104
Содержание DYNAPAC CC224C
Страница 2: ......
Страница 16: ...Introduction 4812159701_D pdf 2021 03 16 4...
Страница 26: ...Special instructions 4812159701_D pdf 2021 03 16 14...
Страница 43: ...Machine description 4812159701_D pdf 2021 03 16 4812129673 Warning CALIFORNIA Proposition 65 31...
Страница 90: ...Operation 4812159701_D pdf 2021 03 16 78...
Страница 104: ...Preventive maintenance 4812159701_D pdf 2021 03 16 92...
Страница 124: ...Maintenance 10h 4812159701_D pdf 2021 03 16 112...
Страница 128: ...Maintenance 50h 4812159701_D pdf 2021 03 16 116...
Страница 168: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...