Technical specifications
4812159701_D.pdf
2021-03-16
Technical specifications
Vibrations - Operator station
(ISO 2631)
The vibration levels are measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, with vibration switched
on, on soft polymer material and with the operator’s seat in the transport position.
The vibration levels are measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, with vibration switched
on, on soft polymer material and with the operator’s seat in the transport position.
Measured whole-body vibrations are below the action value of 0.5 m/s² as specified in Directive
2002/44/EC. (Limit is 1.15 m/s²)
Measured whole-body vibrations are below the action value of 0.5 m/s² as specified in Directive
2002/44/EC. (Limit is 1.15 m/s²)
Measured hand/arm vibrations also were below the action level of 2.5 m/s² specified in the same
directive. (Limit is 5 m/s²)
Measured hand/arm vibrations also were below the action level of 2.5 m/s² specified in the same
directive. (Limit is 5 m/s²)
Noise level
The noise level is measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, on soft polymer
material with vibration switched on and the operator's seat in the transport position.
The noise level is measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, on soft polymer
material with vibration switched on and the operator's seat in the transport position.
Guaranteed sound power level, L
wA
55/60kW
106 dB (A)
Guaranteed sound power level, L
wA
55/60kW
106 dB (A)
74/75kW
107 dB (A)
74/75kW
107 dB (A)
Sound pressure level at the operator's ear (platform), L
pA
91 ±3 dB (A)
Sound pressure level at the operator's ear (platform), L
pA
91 ±3 dB (A)
Sound pressure level at the operator's ear (cab), L
pA
85 ±3 dB (A)
Sound pressure level at the operator's ear (cab), L
pA
85 ±3 dB (A)
During operation the above values may differ because of the actual operational
conditions.
During operation the above values may differ because of the actual operational
conditions.
Electrical system
Machines are EMC tested in accordance with EN
13309:2000 'Construction machinery'
Slopes
Max 20° or 36%
Max 20° or 36%
The recommended max slope angle is for a machine
that runs straight on hard, flat surface.
Unstable ground, vibration on, speed and steering the
machine can all cause the machine to topple at
smaller angles than specified here.
15
Содержание DYNAPAC CC224C
Страница 2: ......
Страница 16: ...Introduction 4812159701_D pdf 2021 03 16 4...
Страница 26: ...Special instructions 4812159701_D pdf 2021 03 16 14...
Страница 43: ...Machine description 4812159701_D pdf 2021 03 16 4812129673 Warning CALIFORNIA Proposition 65 31...
Страница 90: ...Operation 4812159701_D pdf 2021 03 16 78...
Страница 104: ...Preventive maintenance 4812159701_D pdf 2021 03 16 92...
Страница 124: ...Maintenance 10h 4812159701_D pdf 2021 03 16 112...
Страница 128: ...Maintenance 50h 4812159701_D pdf 2021 03 16 116...
Страница 168: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...