56
Appendix
HOSP-200
➔
Loads homing speed (backward)
HP1
➔
Rising edge will be registered at
the limit switch
ENPROG
➔
Program will activate after
power on
ANSW0
➔
No asynchronus answering
EEPSAV
➔
Saves configuration
Program:
GOHIX
➔
Homing with the Hall index zero
A1
HP3
➔
Logic level high is registered at
input 2 (Fault Pin Input)
A2
JPF2
➔
Continuous loop until the logic
level is low at input 2
HP1
➔
Logic level low is registered at
input 2 (Fault Pin Input)
A3
JPF3
➔
Continuous loop until logic level
is high at input 2 ... evaluation
of the positive edge
LR5000
NP
M
➔
5 revolutions forward
DELAY50
➔
0.5 second delay then evaluate
input 2
JPF1
➔
When low logic is registered at
input 2, jump to the beginning
of the program
LA0
NP0
M
➔
Run to position 0 if high logic
level at input 2
JMP1
➔
Jump to the beginning
Commentary:
■
After programming is complete the RS-232
connection is no longer necessary.
■
The program is started with a short pulse at
the digital input and interrupted with a long
pulse.