48
Appendix
Commands for Additional Modes
Command Function
Description
Example
CONTMOD *)
Continuous Mode
Switches from the present further mode back to
CONTMOD
continuous operating mode. (Hall Sensor gives
actual position. Communication over the RS-232)
STEPMOD *)
Steppermotor Mode
Switches to stepper motor mode.
STEPMOD
STW *)
Load Step Width
Sends a step width to the motor.
STW1
STN *)
Load Step Number
Send a step number to the motor
STN1000
GSTW
Get Step Width
Calls up step width
GSTW
➔
1
GSTN
Get Step Number
Calls up step number
GSTN
➔
1000
GEARMOD *)
Gearing Mode
Switches to gearing mode
GEARMOD
APCMOD *)
Analog Position
Switches to analog positioning mode
APCMOD
Control
ENCMOD *)
Encoder Mode
Switches to encoder mode. Uses external
ENCMOD
encoder for actual position. (Upon switching the
position is automatically set to 0)
HALLSPEED *) Hall Sensor as
Actual speed is given by the Hall Sensors.
HALLSPEED
Speed Sensor
ENCSPEED *)
Encoder as
Actual speed is given by the external encoder.
ENCSPEED
Speed Sensor
ENCRES *)
Load Encoder
Sends the encoder resolution to the motor.
ENCRES512
Resolution
Range: 0 to 65535 [4 x (Pulse/Revolution)]
GENCRES
Get Encoder
Calls up the resolution of the external encoder
GENCRES
Resolution
➔
512
VOLTMOD *)
Set Voltage Mode
Switches to voltage regulator mode.
VOLTMOD
GMOD
Get Mode
Calls up the present mode.
GMOD
➔
c
c ... normal operating mode
s ... stepper motor mode
a ... analog positioning mode
e ... encoder mode, speed at the external encoder
h ... encoder mode, speed at the Hall Sensors
g ... gearing mode
v ... voltage regulator mode