Handling Errors and the Error Output
34
The Error Output as a Digital Output
Aside from the ability to function as a limit switch input (REFIN)
and a direction of rotation input (DIRIN), the error output can
also function as a digital output. This makes it possible, for
example, to control a valve directly or to send a signal as a
reaction to a certain event.
Command Function
Description Example
DIGOUT *) Digital Output
Programs the error output
DIGOUT
as a digital output.
The output is set to
logic level LOW
CO *)
Clear Output
Sets digital output to logic
CO
level LOW
SO *)
Set Output
Sets digital output to logic
SO
level HIGH
The last setting will be saved with the EEPSAV command.
Command Function
Description Example
DCE*)
Delayed Current
Delayed activation of the
DCE100
Error
error display for current
limiting, over voltage
protection, and deviation
error. Given in 1/100th seconds.
GDCE
Get Delayed
Calls up the delayed current
GDCE
Current Error
error value
➔
200
Default Setting: DCE200 … 2 second delay
Example:
DCE400
➔
The delay time is set to 4 seconds.
Short periods of overload as can occur in the acceleration phase
will be ignored. If the motor is in current limiting for more than
four seconds the error will be activated.