Configuring the Velocity Control
Setting the Direction of Rotation
Command Function
Description
Example
ADL *)
Analog
Armature rotates left with positive
ADL
Direction
voltage at the analog input
Left
ADR *)
Analog
Armature rotates right with positive ADR
Direction
voltage at the analog input
Right
Default Setting: ADR ... Right rotation with positive voltage.
b.) Command Velocity with Pulse Width Modulation (PWM) at
the Analog Input
The factory setting are:
■
Pulse Duty Ratio > 50%
➔
Rotation Right
■
Pulse Duty Ratio = 50%
➔
Rotation Stop
■
Pulse Duty Ratio < 50%
➔
Rotation Left
The commands SP, MV, MAV, ADL, and ADR can also be used in
this mode.
c.) Command Velocity at the RS-232 Port
Command Function
Description
Example
V *)
Select
Activates velocity control mode
V2000
Velocity
and rotates with the given value.
Mode
GV
Get Velocity Calls up the command velocity
GV
➔
500
Directly following the SOR0-Command the motor continues
rotating with the current command velocity.
Special Setting: Constant Velocity
SOR0 [enter]
➔
Switches to RS-232 Mode
V500 [enter]
➔
Enter desired velocity
EEPSAV [enter]
➔
Saves setting to EEPROM
Now the motor will always start with the saved velocity.