Protection Function
Alarm check and Release
11-3.
If an alarm occurs, remove its cause and then release it. The alarm can be released as follows.
In case of alarms of which ‘Reset ’column is indicated to ‘Invalid’, power must get down prior
to releasing the alarms
Flash
Count
Alarm Name
Description
Reset
1
Overcurrent
1)Check the motor’s short-circuit (A, /A, B, /B)
2)Check the mechanical status such as parameter setting.
Valid
2
Overspeed
1)Check parameter setting, and abnormal operation of the
motor.
2)Check the speed command of upper controller(ex:PLC).
Valid
5
Overheat
1)Get down the ambient temperature or install a cooling fan.
2)Check the distance is over 50mm between drivers.
Valid
6
Over
regeneratived
voltage
1)In case of high-speed operation, check if the acceleration
or deceleration speed is low.
Valid
7
Motor connection 1)Check the connection status of drive and motor.
Invalid
12
ROM error
1)Contact to distributor.
Invalid
14
Drive voltage error 1)Check if power is supplied to the drive.
Invalid
50
Internal
communication
1) Power on the drive again.
Invalid
51,60 STEP ON failure
1) Pass the STEP ON command again.
2) Power on the drive again.
Valid
201
IP setting error
1) Set the last number of IP and Gateway differently.
2) If using the basic IP address, set the IP setting from 2 to
254
Invalid
202
IP conflict
1) IP conflict with other drives (including other products), so
check the settings of each drive (including other products).
Invalid
Содержание Ezi-Step II Plus-E
Страница 1: ... Rev 03 User Manual Text ...
Страница 8: ...www fastech co kr Specifications of the Drive 8 ...
Страница 11: ...www fastech co kr 11 Specifications size of the Motor Motor Size 3 2 ...
Страница 12: ...www fastech co kr Specifications size of the Motor 12 ...
Страница 16: ...www fastech co kr Configuration 16 Controller configuration 4 2 1 General Drive For 20 60 mm motor ...
Страница 17: ...www fastech co kr 17 Configuration 2 86 mm motor drive ...
Страница 18: ...www fastech co kr Configuration 18 External Wiring Diagram 4 3 1 General Drive For 20 60 mm motor ...
Страница 19: ...www fastech co kr 19 Configuration 2 86 mm Motor Drive ...
Страница 67: ...www fastech co kr 67 Appendix Brake Installed Motor Specification and Size 12 3 ...