Control I/O signal
11) E-Stop Input
When [Emergency stop] signal is set to [ON] the current motion is stopped immediately
without deceleration. E-Stop signal is active in ON level and pulse scale is 10ms or more.
12) JPT Input0~Input2 (Jump Position Table Input)
Input
Select motion pattern (position table number) to be subsequently executed according to
input signal conditions.
【Example】 If PT 14 motion operates, when there is no other input signal, next motion
becomes PT 15 as shown in Figure 1). However, if ‘JPT Input0~Input2’ input signal is set to ON
while PT 14 is executing, each corresponding position number is executed as shown in Figure
2)~4).
PT 14 Data
PT No
…
JP Table No.
JPT 0
JPT 1
JPT 2
14
…
15
115
116
225
Motion Pattern