9.
Remove the Shipping Skids:
The shipping skids can be removed by lifting and supporting the vendor with an approved lifting device
and then remove the (4) leveling legs using a 1 3/8” socket wrench. Re-install the leveling legs a
minimum of ¾ “. Store shipping skids for future use.
The shipping skids have center cuts (kerfs) cut through each end and between the leveling legs to allow
skids to be split in half and removed using a pry bar if necessary. Please note, splitting the skids will
render them unusable in the future. The shipping skids will need to be replaced before the machine is
moved again. Adjustable feet will bend / break if shipped without a shipping skid.
10.
Adjust the front leveling legs
Level the cabinet using the included bubble level to less than 2° of being level. All legs must be in solid contact
with the ground. A maximum of 1” of thread is visible when the leveling leg is fully extended. Do not extend the
leg beyond this point. Leveling legs are adjusted using an adjustable wrench, pliers or a 1-3/8” open end wrench.
Unscrewing / adjusting the legs down will raise the machine approximately 1/16” per turn of the foot in that
corner. If the machine is to be used next to another vendor, compare the top and side for proper alignment.
Minimum leg extensions should be used in leveling and alignment to attain greater stability. Make sure that all the
leveling legs are in contact with the floor and that the machine does not rock. If you cannot level the vendor,
select another location. Do not place any objects under the machine. Leveling is extremely important to ensure
proper vendor operation and robot function. Do not program or operate the machine before the leveling process
is complete. If preprogramming selections in a warehouse prior to placement, the machine must be leveled again
at the new location and all the program selections checked for proper robot to bin alignment.
11.
INSTALLING AND POSITIONING THE MACHINE
1.
Maintain a distance of at least 3” (7.6 cm) between the rear wall of the vendor and any obstructions to ensure
adequate ventilation airflow. If enclosed / built in, airflow in the bottom and out the top must not be obstructed or
blocked.
2.
Opening the Front Door: The T-Handle keys (if locks are supplied,) can be found in the coin change pocket. The T-
Handle lock cylinder and keys that come with each DIVI Vendor are common to all machines shipped from Fastcorp,
LLC. All shipping locks should be replaced before the machine is placed on location.
3.
Power Supply Cord: The 115v DIVI Vendor power supply cord is equipped with a resettable Ground Fault Circuit
Interrupt device (GFCI). Care should be taken when handling the GFCI module. Damage may occur if dropped onto a
hard surface. The GFCI unit has an LED light to let you know that the device is working properly. If the GFCI cannot
be reset or if the GFCI unit trips immediately after being reset, a replacement cord may be necessary. Contact
Fastcorp Service at (888) 441-3278.
4.
Verify the machine is level with the included bubble level.
Содержание DIVI
Страница 56: ...Fastcorp LLC DIVI Setup and Users Guide Page 56 of 62 Rev 6 Display Assembly Freezer Lid Closed Switch...
Страница 61: ...Fastcorp LLC DIVI Setup and Users Guide Page 61 of 62 Rev 6...
Страница 62: ...Fastcorp LLC DIVI Setup and Users Guide Page 62 of 62 Rev 6 VMC Connector layout...