Do not plug machine into a power strip, extension cord, or power splitter. Machine must be plugged
directly into an appropriate wall outlet.
Power cord should extend out or down out of wall outlet to prevent wire strain. If wire extends up from
wall outlet an electrician must be called in to flip the wall plug to prevent cord strain and failure.
Do not crush the power cord when moving the machine.
Do not unplug machine by pulling on the power cord. It must be unplugged by gripping the plug and
pulling.
Do not use electrical appliances inside the food storage compartments of this machine.
Do not replace fuses with any other than the standard fuse. Reference the fuse table in this manual or the
fuse table in your machine.
Failure to comply with electrical / power safety warnings and requirements above could result in a damaged
power cord. A damaged cord could cause electrical shock, fire, fire hazard, and death. Do not plug in machine If
the power cord is showing signs of wear, cracks, abrasion, crush, or pinch damage. Damaged cords must be
replaced. Contact Fastcorp to order a replacement cord.
C.
GROUND THE VENDOR
The DIVI Vendor MUST be properly grounded. It must be plugged into a properly grounded outlet that
complies with state and local codes. If the outlet will not accept the power cord plug, contact an electrician to
install an appropriate AC outlet and line if necessary that meets local codes.
Never use gas pipes, plastic water pipe, telephone lines, or other inappropriate connections as a grounding
source.
The machine must be properly grounded to prevent any power leakages or electrical shocks caused by current
leakage from the machine.
Do not remove the ground pin or in any way bypass, modify, defeat, or destroy the grounding system
of the vendor.
Do not bypass, defeat, destroy, or replace the power cord with a non GFCI cord if the machine was
originally equipped with a GFCI (ground fault circuit interrupter) cord (all 110v Divi machines.)
Failure to comply with proper grounding listed above may result in shock, electrocution, burn,
explosion, and death.
D.
General Maintenance
Lubrication
With the exception of the robot hose drive bearings, do not use oil or any other lubricants on moving parts.
Lubricants may damage the mechanical and electronic components.
3 in 1 oil may be used very sparingly on
hose drive bearings. These do not require oil but occasionally can squeak. 3 in 1 oil will stop the squeak.
WD40 and other spray oils
are not to be used
on components in this machine.
E.
Cleaning Considerations and Requirements
It is important to maintain the machine in accordance with this manual. The cabinet, freezer, door, and
delivery bin should be periodically wiped down with a non-abrasive damp cloth and vacuumed as necessary.
Children and
persons with reduced physical, sensory, mental capabilities, experience, and / or knowledge
should not clean or maintain this machine unless they have supervision or instruction concerning use of the
appliance by a person responsible for their safety.