![Farfisa EH9262CW series Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/farfisa/eh9262cw-series/eh9262cw-series_technical-manual_3567673024.webp)
2.
14
(MT13 - En 2015)
TA2160
. Table adapter for ML2002C videointercom. Complete with junction box and 2.4m
connection cable with 20 wires.
- Fix the wall adaptor WA2160W to the table adaptor using
the supplied nuts.
- Insert the cable in the proper hole of the adaptor and fix it.
- Make the connection on the video intercom terminal
boards and write down the correspondence between
terminals and wire’s colour on the label on the junction
box.
- Connect the wires of the system to the terminals of the
junction box.
- Fix the videointercom as shown in the figure 2 on page
2.13.
Yellow
Junction box
LM
LM
EH9262..
LM
LM
LM
Table version
WA2160W
TA2160
Selecting the closing impedance
Videointercoms are provided on the back with a jumper J2 that, when set in the correct
position, readjusts the signal coming from the riser to ensure the correct operation of the
connected systems.
J2
Jumper to select impedance termination line
Additional functions
Call floor
To receive a floor call you must connect a button (FP) between
terminals A1 and GN of the videointercom.
When the button FP is pressed, the videointercom speaker will
receive a call different from calls from the external stations. The
call is received also if the videointercom is in conversation.
Call repeater
To relaunch the call of the videointercom
in other parts of the apartment add a relay
1471E and a transformer PRS210.
ADJUSTMENTS
The audio levels are set in the factory; settings
on the back of the device must be changed
only if really necessary.
Setting the sound levels.
- If audio is excessively intermittent during
the conversation or the speaker tends to
distort it during the call, it is recommended
to slightly change the microphone sensitivity
using the SENS trimmer on the back of the
video-intercom.
- In case of problems in getting the line in one
of the two directions, slightly increase the
level of the disturbed channel and decrease
the level of the other channel using the
VOL trimmer for the microphone volume
and the menu buttons for the speaker volume
(see chapter "Audio-video adjustment" on
page 2.20).
2-3
termination 15
Ω
Ω
Ω
Ω
Ω
1-2
termination 100
Ω
Ω
Ω
Ω
Ω
(default)
3-4
open line
INTERNAL STATIONS
ML2002C
GC
LM
A1
LM
GN
GE
2
1
3
4
J2
3
2
1
J1
J2
4
3
2
1
GC
LM
A1
LM
GN
GE
2
1
3
4
J2
3
2
1
J1
Adjusting microphone level
Adjusting microphone sensitivity
1 2 3 4
1 2 3 4
1 2 3 4
one
GE
GC
PRS210
230V
127V
0
1471E
9T
1
6
7
5
max 50V-5A
ML2002C