![Farfisa EH9262CW series Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/farfisa/eh9262cw-series/eh9262cw-series_technical-manual_3567673152.webp)
4.
40
(MT13 - En 2015)
Programming example of actuator with the following features:
Relay - Address: 215
;
Activation time: 5 seconds
;
Operating mode: monostable, activation from external door stations permitted, master
IN/OUT port
(configured as OUT. Jumper J2 in position 2-3)
; Address: 216
;
Activation time: 30 seconds
;
Operating mode: monostable, activation from external door stations not
permitted, master, output
SERVICE MODULES