- 11
-
Mi 2578
EN
GLISH
FR
ANÇAIS
ES
PAÑOL
P
OR
T
UGUÊS
DE
UTSCH
IT
ALIANO
enter the new address; enter 255 to erase a
value previously entered;
press button
to confirm;
continue with the next programming or exit
programming.
Programming the address of the service
activated by closing contact A1/GN (code
018).
When the input terminals A1 and GN of the
intercom are closed by means of a button,
the floor call is activated (the intercom rings
with the melody programmed for this type of
call, without enabling the conversation). It is
possible to associate an address to the input
if, you want to relaunch the same call to other
extensions as well without connecting the
same button to them as well. The addresses
that can be configured are listed below:
- addresses 001-200: floor call sent to another
user; in the case the address chosen is the same
of the user address set on the dip-switches,
the call is relaunched to all other extensions
in the apartment;
- addresses 201-210: send alarm to concierge
unit;
- address 255: delete previously entered value.
To program the address associated with clos-
ing contacts A1/GN (by default empty), it is
necessary to:
enter code 018;
press button
;
o confirm;
enter the new address; enter 255 to erase a
value previously entered;
press button
to confirm;
continue with the next programming or exit
programming.
Programming ringtones (codes 020 to
028).
The following parameters can be programmed
in relation to the ringtones. First dial the
code (020-028) and then the value to be set:
-code 020: code identifying the common vol
-
ume level associated with all the ringtones
(factory value 3, permitted values from 1=min
-
imum to 5=maximum);
-codes 021, 022, 023 and 024: the four codes
identify the ringtone set for calls from the
external door station, from intercom within
the same flat, from another flat and from the
floor respectively (see table 1 for the factory
settings;)
- codes 025, 026, 027 and 028: the four codes
identify the number of rings associated to
the ringtone set for calls from external door
station, intercom inside the same flat, from
another flat and from floor respectively (for
factory settings see table 1, allowed values
from 1 to 5).
To perform the desired programming it is
necessary:
enter one of the codes from 020 to 028;
press button
to confirm;
enter the new value to be assigned;
press button
to confirm;
continue with the next programming or exit
programming.
Programming the automatic answering
(code 029).
If the intercom is installed in a context where
it is not possible or not convenient to press a
button to answer the call,(like in a restaurant
is kitchen or in some office), it is possible to
enable the automatic answering. When the call
is received, after 4 seconds, the conversation
is automatically established, without pressing
any key. Programming the function (disabled
by default) is described below:
enter code 029;
press button
to confirm;
enter
the value 002 to enable
the automatic
answering; enter the value 000 to disable it;
press button
to confirm;
continue with the next programming or exit
programming.
Note:
If automatic answering has been
enabled, long pressure of the
button
will not enable ringtone exclusion.
Return to factory defaults
To return to the factory settings, it is neces-
sary to:
enter programming mode
following the
instructions described in the paragraph
"Entering programming mode",
press the following buttons in this se-
quence:
, 2 ,1 and
;
the
icon LED stops flashing, the
icon
LED lights up for one second and then the
icon LED returns to flashing slowly;
exit programming. If new programming is
required, re-enter and perform the neces-
sary steps.
Attention:
returning to the factory
defaults has no effect on the user
address, which is set manually via the
dip-switches.
Programming talk volume level with ex-
ternal door stations.
It is possible to modify the intercom volume
level during conversation with the door unit.
The procedure to follow is as described below:
during a conversation with one of the
system's external door stations, press
buttons: 1 and 2 simultaneously;
the icon LED
starts flashing;
using
keys 1 to increase and 2 to decrease
, it is
possible to change the volume level. Eight
levels are available: when the maximum or
minimum level is reached, an acoustic signal
is emitted. Once the desired level has been
reached, wait a few seconds to automatical-
ly exit the setting mode. The icon LED
returns to steady light.
Note
The level set in this way is memorised
and used in all subsequent conversations.
Returning to the factory settings also
affects this parameter.
Programming talk volume level with in-
ternal stations.
It is possible to modify the intercom volume
level during conversation with another user.
The procedure to follow is as described below:
during a conversation with one of the sy-
stem's apartment stations, press buttons:
1 and 2 simultaneously;
the icon LED
starts flashing;
using
keys 1 to increase and 2 to decrease
, it is
possible to change the volume level. Eight
levels are available: when the maximum or
minimum level is reached, an acoustic signal
is emitted. Once the desired level has been
reached, wait a few seconds to automatical-
ly exit the setting mode. The icon LED
returns to steady light.
Note
The level set in this way is memori-
sed and used in all subsequent intercom
conversations. Returning to the factory