TA3160
. Table adapter complete with junction box and 2.4m connection cable with 20
wires.
- Remove the cover to the junction box.
- Make the connection on the video intercom
terminal boards and write down the
correspondence between terminals and
wire’s colour on the label on the junction
box.
- Connect the wires of the system to the
terminals of the junction box.
- Fix the videointercom as shown on page
2.39.
WB3262
LM
LM
LM
GC
LM
LM
A1
GE
GN
1
J1
2 3 4
Yellow
Junction box
Table version
PROGRAMMING
The videointercom must be suitably programmed for
operation.
Two programming modes are available:
-automatic (quick programming of user code acting
from external station);
-manual (programming of all videointercom functions)
The following programming is possible:
- user address;
- internal address;
- address to assign to button “
”; maximum 4
addresses of external door stations;
- code to assign to buttons “1”, “2”, “3”, “4”, and "5"
to make intercom calls, door station monitoring or
for special services;
- selection of the call timing and call melody for 4
different call melodies (see table 2.8).
Factory setting
- user address
= 100
- internal address = 000
- buttons “
”, “1”, “2”, “3”, “4”, "5" = no codes are
stored to the buttons
- number of call rings and call melody (see table
2.8)
Attention: it is mandatory to program the equipment
only with the user code (address) all other
programming are optional.
Enter the programming mode
Hold the button
pressed for more than 4 sec-
onds and pick up the handset after the confirmation
tone; the yellow LED turns on and stays on for the
entire programming selection phase.
Release the button
.
If for 2 minutes no keys are pressed, system switches
back to the operating mode.
Exit the programming phase
You can exit the programming mode at any time by
replacing the handset; yellow LED turns-OFF.
Automatic programming
You can use the automatic programming mode to
save the videointercom address from the external
station. To enter the automatic programming mode
you must:
enter the programming mode following the
instructions described in “Enter the programming
mode”;
make a call from an external station within 2
minutes. In case of installations with digital push-
button keyboard TD2100, key in the number you
want to assign to the videointercom and press “
”.
In case of installations with digital encoder
Selecting the closing impedance
The wall bracket WB3262 are provided with the jumper J1 that, when placed in the correct
position, allows to readapt the signal from the riser for the correct operation of the
connected devices.
J1
Jumper to select impedance video signal
Adjusting brightness and contrast (or color)
2-3
termination 15
Ω
Ω
Ω
Ω
Ω
1-2
termination 100
Ω
Ω
Ω
Ω
Ω
(default)
3-4
open line
1 2 3 4
1 2 3 4
1 2 3 4
Table 2.8.
Factory setting for calls
Melody
Calls
Timing
Type
from door station
1
Din-Don
intercommunicating
4
Dring 1
from other users
4
Dring 2
floor (local)
1
Dring 3