39
(MT13 - En 2015)
4
Position 1-2
(power supply with additional
transformer)
Position 2-3
(power supply from line -
default setting)
SERVICE MODULES
Table 4.10 -
Relay operating mode
(1)
Code
0
1
2
3
4
5
6
7
monostable
bistable
activation from door stations
master
slave
(1)
If you need to code multiple relays with the same address in the
installation, you must programme only one relay as MASTER and all
the other relays with the same address as SLAVE.
Table 4.11 - IN/OUT port operating mode
(2)
Code
0
1
2
3
4
5
6
7
8
monostable
bistable
activation from door stations
master
slave
output
input
(2)
If you need to code multiple IN/OUT ports with the same address in the
installation, you must programme only one port as MASTER and all the
other ports with the same address as SLAVE.
Resetting the default programming values
To reset the actuator default programming values and delete all the
variations made in the programming mode you must.
enter the programming mode as described in the “Entering the
programming mode” section;
hold the key SW1 pressed; after 2 seconds the LED starts flashing
rapidly; after other 2 seconds the LED turns off, turns on again and stays
on;
release the key SW1;
move the jumper J5, from position 2-3 to position 1-2 to exist the
programming mode.
Selecting the actuator power supply mode
The actuator can be directly powered from the line or with 12V alternate
voltage applied to the two terminals
/
.
To select the power supply mode close the jumper J1 in pins 2-3 to select
power supply from the line (default setting) or in pins 1-2 to select an
additional power supply source.
Configuring the COM terminal of the IN/OUT port
To configure the COM terminal of the IN/OUT port (configured as OUT
output by default), after programming the relay and IN/OUT port
operating modes as described above, you must set the jumper J2 to
associate the COM terminal to the IN terminal, if the port is used as
input, or to the OUT terminal if the port is used as output (see table
4.12).
Integration in installation with DUO technology
To activate the actuator relay or IN/OUT port, you must perform two
additional operations in the devices of the installation:
in the button of the internal stations ("actuations" for Zhero series;
"contacts" for myLogic series) where you want to activate the
service (for information on programming see the instructions manual
of the internal station), you must store the same address assigned
to the actuator relay or IN/OUT port.
if one or more actuators are connected to line L2 of the exchanger
art. 2273, you must reserve one of the 4 numerical intervals of the
exchanger to the address of the actuator or actuators connected to
line L2. In this case you must use consecutive codes (211 - 212 - 213
- 214 - 215 - 216, etc.) for the relay and port addresses.
To perform this operation you must:
- set the exchanger in wait-for-programming mode for the selected
numerical interval (see page 4.19);
- in the actuator or actuators connected to line L2 of the exchanger
(*), enter the programming mode and press the key SW1 of the first
actuator twice; then press the key SW1 twice in all the other
actuators. When you press the key for the first time, the actuator
sends the address of the relay that was programmed previously to
the exchanger; when you press the key for the second time the
actuator sends the IN/OUT port address; press the key SW1 twice
also if no address was assigned to the relay or port.
- in all articles perform the operations to exit the programming mode.
(*) if the actuator (or actuators) is connected to line L1 of the exchanger,
NO programming operation must be performed.
Table 4.12
Position
Terminals
Activation
jumpers
activation
command in:
J2
COM OUT
IN
1-2
YES NO
YES
Input
2-3
YES YES NO
Output
position 1-2
(activation of IN terminal - input
command)
position 2-3
(activation of OUT terminal - output
command - default setting)
(2-3
default setting
)
Position of
button SW1
in actuator
Example: if you want to actuate an
automatic gate controlled by the relay of
an actuator connected to terminals L2 of
one of the exchangers of the main
entrances with the button ”1” of a
videointercom Exhito, you must:
1) program the address, time and
operating mode of the actuator relay;
2) program the button ”1” of the video intercom used to open the gate
with the address of the relay you want to activate;
3) program a numerical interval of the exchanger, different from any
other numerical intervals used, with the address of the relay you
want to activate.
Note. Do not perform the operation described in 3 if the actuator is
connected to line L1 of the exchanger.