![Farfisa AD2121CAG series Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/farfisa/ad2121cag-series/ad2121cag-series_technical-manual_544905107.webp)
3.
41
(MT13 - En 2015)
3
jumper for pro-
gramming
Connection terminal boards
to the DUO
digital line
CD2131MAS.
Encoding module with front
plate and one stainless steel button. Complete
with name-holders with transparent screen
green backlighting, breaking resistant and with
connection cable to the next module.
Used to send calls over DUO digital line.
CD2132MAS.
With 2 call buttons.
CD2134MAS.
With 4 call buttons.
Technical features
Power supply from audio/video module
Door-opening time
3 / 6 seconds
Number of calls
128
Default address
231
Address 1
rt
push-button (default)
100
Dimensions
1 module
Operating temperature
0°÷+40°C
Maximum humidity acceptable
90% RH
Terminals
LP/LP audio-data-video to and from internal
users
EC
positive signal for auxiliary service
EM
negative signal for auxiliary service
S1/S2 door opening contacts
DIGITAL ENCODER
flat cable for connection
to audio/video module
DOOR STATIONS
DIGITAL ENCODER
to electric door
lock and auxiliary
services
PROGRAMMING
(instruction for article with software
AF100 or higher)
To program the device it is necessary
to perform the following phases:
1) enter programming mode
2) insert code of desired program-
ming
3) insert required address or func-
tional code
4) exit programming mode
Notes
- In any situation it would be possible
to exit the programming phase fol-
lowing the instructions reported on
paragraph 4.
- To proceed with other programming
repeat the phases 2 and 3.
flat cable for the connec-
tion of additional modules
MA24S
SW1 programming button
programming micro-
switches MS1-MS2
LP
LP
J1
J1
1-2
2-3
J1
1
1
2
2
3
3
1) ENTERING THE PROGRAMMING MODE
Move the jumper J1 from 2-3 to 1-2 position; a
programming tone will confirm the correct operation.
Position of jumper J1
2) I
NSERT CODE OF DESIRED PROGRAMMING
On the microswitches MS1 and MS2 set the code
corresponding to the programming operation you
wish to enter as reported on table 3.11 on page 3.42
(codes 1A, 2A, 1B, 2B, 1C, 1E and AA).
Press the programming button SW1.
3)
INSERT REQUIRED ADDRESS OR FUNC-
TIONAL CODE
On the microswitches MS1 and MS2 set the address
you wish to enter in accordance with the cross-
references re-
ported on table 3.7
on the pages 3.23,
3.24 and 3.25.
For system pro-
gramming see
table 3.12 on the
page 3.42 (code
2B).
Press the programming button SW1.
- Repeat phases 2 and 3 until you have completely
programmed the digital encoder.
- Any time you press the SW1 button an acknowledge
or error tone will warning you whether the entered
code is correct or not; in case of incorrect code you
must enter again the correct one.
4)
EXIT PROGRAMMING MODE
To exit the programming phase it is necessary to set
OFF all the microswitches MS1 and MS2 and move
back the jumper J1 from 1-2 to 2-3 position.
1-2 = program-
ming mode
2-3 = operating
mode
MS1
ON
1 2 3 4
ON
1 2 3 4
MS2