![Farfisa AD2121CAG series Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/farfisa/ad2121cag-series/ad2121cag-series_technical-manual_544905109.webp)
3.
43
(MT13 - En 2015)
3
J1
J1
J1
J1
2-3
1-2
1-2
2-3
1
2
2
1
2
3
3
2
+
+
+
+
+
+
+
+
+
+
+
+
+
+
E
NTERING THE
PROGRAMMING MODE
S
ELECTING THE PROGRAMMING TYPE
S
ELECTING THE PROGRAMMING TYPE
S
ELECTING THE PROGRAMMING TYPE
S
ELECTING THE PROGRAMMING TYPE
S
ELECTING THE PROGRAMMING TYPE
S
UPPLEMENTARY CAMERA MODE
(
CODE
255)
S
ETTINGS FOR OPERATIONS WITH A
DOORKEEPER EXCHANGER
(
CODE
201)
S
ET THE DEVICE BACK TO FACTORY SETTINGS
(
CODE
85)
S
ELECTING THE PROGRAMMING TYPE
S
ELECTING THE PROGRAMMING TYPE
E
XIT THE PROGRAMMING MODE
L
AST PUSH
-
BUTTON ADDRESS
(
EXAMPLE
54)
D
OOR STATION ADDRESS
(
EXAMPLE
233)
S
YSTEM PROGRAMMING
(
EXAMPLE
:
-
DOOR LOCK TIME
3
SECONDS
;
-
EXTERNAL DOOR STATION IS ENABLED BY USER
;
-
TONE ON EXTERNAL DOOR STATION IS DISABLED
)
- EC-EM
TERMINALS FOR SUPPLEMENTARY CAMERA
F
IRST PUSH
-
BUTTON ADDRESS
(
EXAMPLE
36)
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
MS1
MS1
MS1
MS1
MS1
MS1
MS1
MS1
MS1
MS1
MS1
MS1
MS1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
MS2
MS2
MS2
MS2
MS2
MS2
MS2
MS2
MS2
MS2
MS2
MS2
MS2
1
1
A
2
1
2
1
Mode
Mode
Mode
Mode
Mode
Mode
Mode
E
C
A
B
A
A
B
ON
ON
1
1
2
2
3
3
4
4
MS1
MS2
+
ON
ON
1
1
2
2
3
3
4
4
MS1
MS2
Example of programming for digital encoders
1) - activation of door lock from turn-ON
button of internal stations. This function can
be activated only during a conversation with the
external door station. In idle state the buttons
will activate the external door station.
Programming operations to be made:
- microswitch 3 of MS2 = position OFF
- microswitch 4 of MS2 = position OFF (3 sec-
onds) or ON (6 seconds)
- code 1E = enter address 250
2) - activation of door lock from button
of internal stations
This programming allows for having two groups
of users connected to a single external door
station, each of them with its own door lock. The
division between the two groups is indicated by
the number that is inserted in the programming
of code 1E. You must insert the first user number
recognised by group 2 that will activate the
door lock connected to terminals EC and EM;
all higher numbers will automatically be in group
2 and will activate the door lock connected to
terminals S1 and S2.
Programming operations to be made:
- microswitch 3 of MS2 = position OFF
- microswitch 4 of MS2 = position OFF (3 sec-
onds) or ON (6 seconds)
- code 1E = insert address of last user in
group 1 (example: if you enter 100 you will
have: group 1 with codes from 1 to 99; group
2 from 100 to 200).
How to deactivate the camera upon call
You can create 2 groups of user addresses that
will not activate the camera during the call from
the external door station. This function is used
to avoid the temporary turn-on of white LEDs in
the colour camera module during calls to
intercoms or actuators 2281.
How to set address groups (codes 4E, 5E,
6E and 7E)
enter the programming mode as illustrated in
“enter the programming mode”;
set code 4E in microswitches MS1 and MS2
and press button SW1; you will hear the
confirmation tone;
set the address number of the first user in
group 1 in microswitches MS1 and MS2
(see table 3.7 on page 3.23);
press button SW1; you will hear the confirma-
tion tone;
set code 5E in microswitches MS1 and MS2
and press button SW1; you will hear the
confirmation tone;
set the address number of the last user in
group 1 and press button SW1; you will hear
the confirmation tone;
repeat the operations above to enter the
address of the first and last user in group 2
(codes 6E and 7E, respectively);
press button SW1 to exit the programming
mode.
DOOR STATIONS
DIGITAL ENCODER