background image

8

 

 

3.9 TEMPERATURE CONTROLLERS

 

a) Remove control panel by undoing fixings at top and 

bottom of control panel and unplug control panel.

 

b)  Disconnect  electrics  loom  and  remove  fixings  to 

enable controller to be removed.

 

c)  Carefully replace in reverse order.

 

 

 

3.10 MAINS ON and HEAT DEMAND NEONS

 

a) Remove control panel by undoing fixings at top and 

bottom of control panel. Disconnect control panel.

 

b)  Remove electrical connections and undo retention nut.

 

c)  Carefully replace in reverse order.

 

 

 

3.11 DRAIN VALVE

 

a) Remove burner as detailed in Section 3.6

 

b) Ensure fry pot is empty. Refer to Section 8.

 

c) Remove nut from handle and lift handle off.

 

d) Remove front panel fasteners.

 

e) Disconnect wiring, noting all connections.

 

f)  Remove front panel to access drain valve.

 

g)  Undo drain pipe. Use appropriate spanner to remove 

drain valve.

 

h) Replace in reverse order and check for oil leaks.

 

 

 

3.12 FILTRATION PUMP

 

a) Remove back panel and flexi-hose at filtration pump.

 

b)  Disconnect electrical coupling plug and connections 

from start.

 

c)  Remove  nuts  from  pump  mounting  bolts  (accessed 

through fryer door at rear of oil bucket compartment) 

and lift pump clear.

 

d) Disconnect pump from bracket.

 

e) Replace in reverse order.

 

Note: Check for oil leaks before replacing any panels.

 

 

 

3.13 IGNITION CONTROL BOX

 

a) Remove rear compartment cover.

 

b)  Unplug  valve  and  control  plugs.  Remove  ignition, 

detector and earth connections.

 

c) Undo three fixings (one at rear, two at front).

 

d) Remove ignition control box.

 

e) Replace in reverse order & test.

 

3.14 TEMPERATURE LIMIT THERMOSTAT

 

a) Open control panel.

 

b) Remove probe and safety thermostat protective cover

 

(ensuring insulation is removed intact).

 

c) Remove phial and probe protective cage inside pan.

 

d)  Undo  two  phial  bracket  retention  nuts  and  remove 

thermostat phial from bracket.

 

e)  Undo  safety  thermostat  capillary  nut.  Using  a  thin 

screwdriver  -  insert  into  boss  from  inside  pan  - 

carefully  tap  capillary  sealing  washers  through  to 

control compartment.

 

f)  Remove thermostat.

 

g) Disconnect thermostat wires.

 

h) Carefully replace in reverse order. Check for oil leaks 

and that thermostat calibration is within specification.

 

 

 
 
 

SECTION 4 - SPARES

 

When  ordering spare  parts,  always  quote  unit  type  and 

serial  number.  This  information  can  be  found  on  data 

plate, located inside fryer door on LH leg support face.

 

Spares List

 

 

Oil bucket 

Fish  plate 

Baskets

 

Splash guard / basket hanger 

Control knob

 

Safety thermostat 

Operating thermocouple 

Ignition box

 

Pump

 

Pilot assembly 

Valve

 

Fast controller 

Neon

 

Mains cable

 

Switches (Pump, reset, on / off)

 

HT (Ignition wires)

 

Injectors (Kit)

 

Содержание G3840

Страница 1: ...er in Charge for reference during servicing Further to this the user instructions should be handed over to the user having had a demonstration of the operation and cleaning of the appliance PREVENTATI...

Страница 2: ...clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unb...

Страница 3: ...learance of at least 150mm to rear between unit and any combustible wall Important If fryer is to be installed with other appliances then the instructions for every model should be consulted to determ...

Страница 4: ...ross 1 7 INJECTOR SIZES Natural Gas Burner Pilot 2 x 2 6mm Polidora G31 2 Propane Gas Burner Pilot 2 x 1 7mm Polidora G25 SECTION 2 ASSEMBLY and COMMISSIONING The gas supply piping and connection to a...

Страница 5: ...n thermostat demands heat i e oil temperature is more than 5 C below temperature setting Extinguishes when desired temperature is reached Figure 3 Additional Controls 3 Burner Lock Out Reset Switch Re...

Страница 6: ...Using The Controller Section 6 2 3 2 5 2 Checking Oil Filtration Pump To check operation of oil filtration pump refer to Section 7 Important After installation the responsible technician should check...

Страница 7: ...m both sides of valve c Disconnect pilot pipe d Remove screws holding valve to bracket e Replace in reverse order Check system for gas leaks f Reset burner pressure as detailed in Section 1 4 3 5 PILO...

Страница 8: ...ace in reverse order Note Check for oil leaks before replacing any panels 3 13 IGNITION CONTROL BOX a Remove rear compartment cover b Unplug valve and control plugs Remove ignition detector and earth...

Страница 9: ...SIONS 187 24 min 26 max Timer Pump Settings Set for 230V Operating thermostat probe Set to 0 8 8 3 6 Setto10minutes 10 Safety thermostat probe Operating and Safety Thermostat Wu Set to Wu 23 17 5 258...

Страница 10: ...r supply failure Please ensure that any plastic coated items are removed prior to use Before operation pan requires to be washed out and thoroughly dried Discolouration of heated parts is caused by fa...

Страница 11: ...oil temperature will then be governed by controller to desired set temperature selected by user on the control knob SECTION 7 CHANGING FILTERING THE OIL Warning After filtering wait 30 seconds before...

Страница 12: ...ll liquid has been drained from fry pot The following procedure should be undertaken AT LEAST DAILY IMPORTANT Disconnect electrical supply before any cleaning commences Warning Oil must be allowed to...

Страница 13: ...rature probe Ensure FAT MELT CYCLE is selected for this process Note Fry plate will lower slowly into fry pot as solid fat melts Warning If fry plate does not sit flat lift plate from centre slightly...

Страница 14: ...SECTION 11 WIRING DIAGRAM for G3840 14...

Страница 15: ...SECTION 11 WIRING DIAGRAM for G3840F 15...

Страница 16: ...CIRCUIT DIAGRAM for G3840 16...

Страница 17: ...CIRCUIT DIAGRAM for G3840F 17...

Отзывы: