5
1
3
2
4
5
3
4
2
1
4
5
2.4.1 G3840 Fryer Control Panel (See Figure 2)
2
3
4
1
2.4.2 G3840 & G3840F - Additional Controls
(See Figure 3)
The following additional controls are located behind
cabinet door.
1. Burner and Temperature Controls ON/OFF Switch
Cuts power to burner and temperature controls.
2. Burner Lockout Indicator
Indicates flame failure.
Figure 2 – G3840 Control Panel
1. ON/OFF and Temperature Control Knob
Temperature Selection (140 - 190°C). (Unit is off when
control is in position indicated).
1
3
2
2. Fat Melt Position
Feature for slow pulsed heating of solid fats.
3. Power on indicator.
4. Heat Demand Indicator
Illuminates when thermostat demands heat, i.e. oil
temperature is more than 5
⁰
C below temperature setting.
Extinguishes when desired temperature is reached.
Figure 3 - Additional Controls
3. Burner Lock-Out Reset Switch
Resets burner for further lighting attempts when burner
lockout indicator is illuminated.
4. Filtration Pump Switch (G3840F only)
Energises filtration pump when burner switch is in
OFF(O) position.
5. Temperature Safety Limiter Reset Button
Located inside red recess, below black cover.
2.4.3 G3840 and G3840F Controller Diagnostic
Indicators (On printed circuit board of
controller, behind control panel)
Green LED ‘ON’ indicates heat demand.
Green LED ‘OFF’ indicates no heat demand.
Red LED flashes if temperature probe is either short or
open circuited.
Red LED is permanently ‘ON’ to indicate system is OK.
Set point is +/-7
⁰
C of mid-set point.
Содержание G3840
Страница 14: ...SECTION 11 WIRING DIAGRAM for G3840 14...
Страница 15: ...SECTION 11 WIRING DIAGRAM for G3840F 15...
Страница 16: ...CIRCUIT DIAGRAM for G3840 16...
Страница 17: ...CIRCUIT DIAGRAM for G3840F 17...