2.4.1 G3840 Fryer Control Panel  (See Figure 2)

 

 

 

2

 

4

 

 

 

1

 

2.4.2 G3840 & G3840F - Additional Controls

 

(See Figure 3)

 

The  following  additional  controls  are  located  behind 

cabinet door.

 

1. Burner and Temperature Controls ON/OFF Switch

 

Cuts power to burner and temperature controls.

 

  

 

2. Burner Lockout Indicator

 

Indicates flame failure.

 

 

 
 

Figure 2 – G3840 Control Panel

 

1. ON/OFF and Temperature Control Knob

 

Temperature Selection (140 - 190°C). (Unit is off when

 

control is in position indicated). 

3  

2

 

2. Fat Melt Position

 

Feature for slow pulsed heating of solid fats.

 

3. Power on indicator.

 

4. Heat Demand Indicator

 

Illuminates  when  thermostat  demands  heat,  i.e.  oil 

temperature is more than 5

C below temperature setting. 

Extinguishes when desired temperature is reached.

 

Figure 3 - Additional Controls

 

3. Burner Lock-Out Reset Switch

 

Resets burner for further lighting attempts when burner 

lockout indicator is illuminated.

 

4. Filtration Pump Switch (G3840F only)

 

Energises  filtration  pump  when  burner  switch  is  in 

OFF(O) position.

 

5. Temperature Safety Limiter Reset Button

 

Located inside red recess, below black cover.

 

 

 

2.4.3 G3840 and G3840F Controller Diagnostic 

Indicators  (On  printed  circuit  board  of 

controller, behind control panel)

 

Green LED ‘ON’ indicates heat demand. 

Green LED ‘OFF’ indicates no heat demand.

 

Red LED flashes if temperature probe is either short or 

open circuited.

 

Red LED is permanently ‘ON’ to indicate system is OK. 

Set point is +/-7

C of mid-set point.

 

Содержание G3840

Страница 1: ...er in Charge for reference during servicing Further to this the user instructions should be handed over to the user having had a demonstration of the operation and cleaning of the appliance PREVENTATI...

Страница 2: ...clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unb...

Страница 3: ...learance of at least 150mm to rear between unit and any combustible wall Important If fryer is to be installed with other appliances then the instructions for every model should be consulted to determ...

Страница 4: ...ross 1 7 INJECTOR SIZES Natural Gas Burner Pilot 2 x 2 6mm Polidora G31 2 Propane Gas Burner Pilot 2 x 1 7mm Polidora G25 SECTION 2 ASSEMBLY and COMMISSIONING The gas supply piping and connection to a...

Страница 5: ...n thermostat demands heat i e oil temperature is more than 5 C below temperature setting Extinguishes when desired temperature is reached Figure 3 Additional Controls 3 Burner Lock Out Reset Switch Re...

Страница 6: ...Using The Controller Section 6 2 3 2 5 2 Checking Oil Filtration Pump To check operation of oil filtration pump refer to Section 7 Important After installation the responsible technician should check...

Страница 7: ...m both sides of valve c Disconnect pilot pipe d Remove screws holding valve to bracket e Replace in reverse order Check system for gas leaks f Reset burner pressure as detailed in Section 1 4 3 5 PILO...

Страница 8: ...ace in reverse order Note Check for oil leaks before replacing any panels 3 13 IGNITION CONTROL BOX a Remove rear compartment cover b Unplug valve and control plugs Remove ignition detector and earth...

Страница 9: ...SIONS 187 24 min 26 max Timer Pump Settings Set for 230V Operating thermostat probe Set to 0 8 8 3 6 Setto10minutes 10 Safety thermostat probe Operating and Safety Thermostat Wu Set to Wu 23 17 5 258...

Страница 10: ...r supply failure Please ensure that any plastic coated items are removed prior to use Before operation pan requires to be washed out and thoroughly dried Discolouration of heated parts is caused by fa...

Страница 11: ...oil temperature will then be governed by controller to desired set temperature selected by user on the control knob SECTION 7 CHANGING FILTERING THE OIL Warning After filtering wait 30 seconds before...

Страница 12: ...ll liquid has been drained from fry pot The following procedure should be undertaken AT LEAST DAILY IMPORTANT Disconnect electrical supply before any cleaning commences Warning Oil must be allowed to...

Страница 13: ...rature probe Ensure FAT MELT CYCLE is selected for this process Note Fry plate will lower slowly into fry pot as solid fat melts Warning If fry plate does not sit flat lift plate from centre slightly...

Страница 14: ...SECTION 11 WIRING DIAGRAM for G3840 14...

Страница 15: ...SECTION 11 WIRING DIAGRAM for G3840F 15...

Страница 16: ...CIRCUIT DIAGRAM for G3840 16...

Страница 17: ...CIRCUIT DIAGRAM for G3840F 17...

Отзывы: